46
GA 5000EAC
OPERATING MANUAL
VERSION 09/2016
ORDER NUMBER DOC2360922
Discharge of electrostatically charged components in
atmospheres containing solvents!
Explosion hazard from electrostatic spark-over.
Use gun only with fi tted nozzle, air cap and union nut.
Tighten the union nut, especially with nozzle in the cleaning
position.
WARNING
7.2.2
GENERAL RULES FOR MAKING ADJUSTMENTS TO THE SPRAY GUN
High-voltage fi eld!
Danger to life from malfunction of heart pacemakers.
Make sure that persons with pacemakers:
Do not work with the electrostatic spray gun.
Do not enter the high-voltage area.
DANGER
High-pressure spray jet!
Danger to life from injecting paint or solvent.
Never reach into the spray jet.
Never point the spray gun at people.
Consult a doctor immediately in the event of skin injuries caused
by paint or solvent. Inform the doctor about the paint or solvent
used.
Never seal defective high-pressure parts; instead relieve the pressure
from them and replace them immediately.
Wear the appropriate protective clothing, gloves, eyewear and
respiratory protection.
WARNING
In the case of unforeseen occurrences, proceed as follows:
1. Switch off control unit.
2. Close the compressed air supply.
3. Relieve pressure according to the operating manual of the product pressure generator.
7.2.1
EMERGENCY DEACTIVATION
Summary of Contents for GA 5000EACEC
Page 2: ......
Page 106: ...106 GA 5000EAC OPERATING MANUAL VERSION 09 2016 ORDER NUMBER DOC2360922 ...
Page 107: ......