76
EPG-SPRINT X
OPERATING MANUAL
VERSION 06/2014
ORDER NUMBER DOC2329371
Fault number
Fault
Cause
Remedy
E43
No fl ow of feed air
No air is fl owing out of the
control unit
Causes:
Gun unplugged during
operation
Check:
Hose kinked / blocked
The hose laying
The air supply to the
control unit
Input pressure > 6 bar
Injector is not connected
Connect injector
Compressed air switched
off
Open compressed air
E51-E53
Exception error
Hardware defect has
occurred
If problem persists, contact
Wagner Service Team
E54
Hardware error
Hardware defect has
occurred
Detach hose on rear of
valve and in standby
mode, check the valve for
seal integrity (air supply
must be connected)
Atomizing air duct valve
leaking
E55
Hardware error
Hardware defect has
occurred
Detach hose on rear of
valve and in standby
mode, check the valve for
seal integrity (air supply
must be connected)
Dosing air duct valve
leaking
E56
Hardware error
Hardware defect has
occurred
Detach hose on rear of
valve and in standby
mode, check the valve for
seal integrity (air supply
must be connected)
Feed air duct valve leaking
E60
Operation without
external release (only
for manual gun with
external control)
No release from
Check external control
Missing or defective
wiring
Summary of Contents for EPG-Sprint X