7. Screw preassembled union nut (12) to gun (1) and tighten by hand.
8. Switch the material pressure back on.
9. Turn the trigger lock (14) to the spraying position and briefl y pull trigger.
10. When the blockage has been fl ushed out secure the gun with trigger lock (14).
11. Relieve the pressure of gun and unit.
12. Unscrew union nut (12).
13. Remove air cap (10) and put ACF5000 nozzle (11) out off air cap by hand. Clean ACF5000
nozzle and insert it in spraying position into the valve housing.
14. Put the air cap (10) on the nozzle (11) and pay attention to the position of the guide
surfaces (X).
15. Screw union nut with attached nozzle guard (9) to the gun body and make sure that
the air cap horns lie in the designated recess (Y).
16. Before tightening the air cap horns (Y) set the desired jet level and then tighten the
union nut to the stop by hand.
17. Switch the material pressure and the air pressure back on.
18. Switch on the control unit.
ACF5000 nozzle in
“cleaning“ position.
ACF5000 nozzle in
“spray“ position.