5. Accessories

Accessories

Description

Order No.

Kit for solar circuit

Accessories for the solar circuit pipe work:
2 filler and drain valves and 2 earth connector clips

190 210 22

Air release kit (not
normally required
because of included air
vent pipe)

Automatic air release kit
Consisting of 2 automatic air release valves and heat resistant ball valves
(up to 200° C), connection 3/8"

190 210 11

Manual air release set
Consisting of 2 Manual Air Release Valves 3/8" and Key

190 210 10

CIRCO –
expansion vessel kit

Expansion vessel for the CIRCO 5 solar circulation unit, operating pressure max.
10 bar, stainless steel connection hose, connection ¾" female with gasket
12 l-volume, incl. wall mounting bracket, pre-pressurised: 1.5 bar
18 l-volume, incl. wall mounting bracket, pre-pressurised: 1.5 bar
24 l-volume, incl. wall mounting bracket, pre-pressurised: 1.5 bar
35 l-volume, with brackets for wall and floor fixing, pre-pressurised: 2.5 bar

150 300 70
150 300 77
150 300 98
150 300 99

Cap check valve for
expansion vessel

Check valve 3/4" with filler and drain valve and with cap against maloperation.

819 200 27

Cylinder mounting kit for
CIRCO 5

Non-adjustable pipe work 1¼" male flat tightening, insulated, adjustable return
pipe for cylinder connections with 400 to 640 mm vertical distance, with 22 mm
sleeves to connect to compression fittings of CIRCO 5

150 301 21

Summary of Contents for CIRCO 5

Page 1: ...lers Controlled heat flow by two temperature resistant non return ball valves Safe deaeration by integrated air venting pipe Variable Installation wall mounting or fitted directly to the storage cylinder the reliable pump station for efficient circulation of the heating fluid in combination with SUNGO controls CIRCO 5 Solar Circulation Unit Function Control through flow meter and thermometers Figu...

Page 2: ...d the appli cation of vacuum tube collectors do require special means of overheating protection like the installation of an auxiliary vessel or alternative positioning of the safety components The CIRCO 5 solar circulation unit can be mounted to a wall or directly to the storage cylinder The CIRCO 5 solar circulation unit must not be mounted outside Norms and guidelines EC conformity declaration T...

Page 3: ... the entire system collector area and heightabove vessel distance vessel to upper edge of collectors Dimensioning scenario system exposed to full sun light but inactive These values are only valid up to about 0 5 litres per m collector volume 0 0 5 1 5 2 0 0 0 1 0 2 0 3 0 m h 3 m s H m econom y 1 0 6 7 5 4 2 1 3 v m axim um Figure 2 Pump characteristics curves CIRCO 5 solar circulation unit Order ...

Page 4: ... numbering fits to numbers in brackets at description of assembling steps items with No 7 8 9 10 12 and 14 are not part of the circulation unit ball valve with integrated thermometer and non return valve air release pipe safety valve compression fitting compression fitting mano meter filler and drain valve circulation pump flow meter with filler and drain valve ...

Page 5: ...com mended to fit in a special cap check valve between flexi ble hose and vessel Connect exhaust pipe 10 to the safety unit and put empty container in place to collect any spills from the pipe The connections to the solar circuit 11 distance of pipes see figure 3 are made by compression fittings 18 or 22 mm figure 6 Cut burr pipes and push into fittings as far as possible then tighten nuts Using t...

Page 6: ...ylinder Connect remaining pipe work In order to prevent forces to the cylinder fixing because of pull from pipe work pipe fixtures should be used at a near wall or at the ceiling The expansion vessel must not be hung from the pump sta tion Apply wall or floor mounting depending on type of vessel Always ensure proper clamping when tightening 32 41 and 46 mm nuts in order to prevent loosening of oth...

Page 7: ...low Stoppers When the circulation pumps are turned of unwanted heat distribution in the solar circuit is prevented by non return ball valves They only open into the flow direction and by pump pressure The ball valve handles can be used to turn them off During operation Filling the system Emptying the system Flow on Ball valve handle vertical Non return valve in operation Flow off Ball valve handle...

Page 8: ...sion vessel kit Expansion vessel for the CIRCO 5 solar circulation unit operating pressure max 10 bar stainless steel connection hose connection female with gasket 12 l volume incl wall mounting bracket pre pressurised 1 5 bar 18 l volume incl wall mounting bracket pre pressurised 1 5 bar 24 l volume incl wall mounting bracket pre pressurised 1 5 bar 35 l volume with brackets for wall and floor fi...

Reviews: