1. To avoid over-discharging your vehicle's battery, we recommend running 
your engine for 10-20 minutes to recharge the vehicle’s battery after every 
2-3 hours of operating the inverter. 
2. If you choose to use on adapter to connect the inverter directly to your 

battery terminals, it is important to connect the '+’ wire to the '+' terminal 
and the ‘-‘ wire to the ‘-‘ terminal. IF YOU CONNECT THE WIRES TO 
THE INCQRRECT TERMINALS, YOU WILL REVERSE THE 
POLARITY AND DAMAGE THE INVERTER. REVERSED 
POLARITY WILL INSTANLY VOID THE WARRANTY OF YOUR 
INVERTER. 

3. If you choose to operate a battery charger to replenish your battery's 

voltage, be sure to disconnect the inverter first.  Failure to disconnect the 
inverter prior to connecting a charger may result in on input spike which 
will damage the inverter. 
CONNECTING THE INVERTER'S INPUT TO BATTERY CHARGER 
WILL VOID THE WARRANTY, AND MAY DAMAGE THE 
INVERTER. 

4

Make sure the battery’s voltage dose not exceed 15 volts DC. 

CONNECTING THE INVERTER TO A DC POWER SOURCE 
GREATER THAN 15 V DC WILL VOID THE WARRANTY, AND MAY 
DAMAGE THE INVERTER. 
 

TROUBLESHOOTING: 

If the inverter does not appear to be functioning properly, there are several 
reasons why the inverter may not be responding: 
 

Problem

Solution

Poor contact 

Clean contact parts thoroughly 

Receptacle has no power 

Check car fuse, replace damage 
fuse. Check receptacle wiring. 
Repair if necessary. 

Fuse is blown 

The fuse is located inside the DC 
plug. Replace fuse with a fuse of 
equivalent value. 

Battery voltage is too low 

Start the engine to recharge the 
battery, replace battery if needed. 

Shut down on overload 

Reduce the wattage of your load to 

lower than 120watt. 

Thermal shutdown 

Under heavy loads fear extended 
periods of time, the inverter will 
shutdown to prevent damage to 
excess heat. Simply reduce your  
load and allow the inverter to cool 
down. 
 

Law-battery shutdown 

Recharge your battery and resume 
operation. If you appear to have a 
problem which is not listed above, 
you may call our customer service 
department at 510-490-9221. 
 

NOTE: 

All specifications typical at nominal line, half load, and  
25°C / 77°F unless otherwise noted. Specifications subjected to change without 
notice. 
 

SPECIFICATION:

 

Output power……………….….……………..120 Watt 
Peak surge….…………………...…………….300 Watt 
Input voltage…………………………………..12V DC 
Output voltage……………..…………110 + / - 5 V AC 
Output frequency…………..………….….60 + / - 5 Hz 
Output waveform………………….Modified sine wave 
Outlet……………….…..North American type 3-prong 
Fuse (replaceable)……………………….….15 Ampere 
Efficiency (full load)…….……………….Approx. 90% 
Dimensions (L x W x H mm)……………...92 x 69 x 21 
Net weight………………………………………...0.5kg 
Power on LED display……………..………………Yes 
Operating temperature……………………55°C +/- 5°C 
No load current…………………………………...<0.1A 
Material………………………….….……….…..Plastic 
 