If an inverter shutdown was preceded by a buzzing sound, there may 

be an excessive load in combination with a low voltage or cable 

problem.

 

ƒ

Normal operating range is 11V to 15V DC.

• AC Outlets — These outlets can supply up to 15 amps at 115V AC 60 Hz
• High Output AC Terminals — There are three insulated terminals on the

front panel of the inverter. These terminals are for connecting 115 volt AC

devices that require more than 15 amps to operate. Other uses are for

connection to distributed wiring that has multiple AC outlets. Remove 2

screws on protective cover to access terminals. Any AC output wiring that

is directly connected must comply with US National Electric Code (NEC)

wiring gauge recommendations. Facing the front panel, the terminals are:

Left

Middle

Right

Neutral

Ground

Live

NEUTRAL and GROUND are bonded inside the inverter to comply with the 

National Electric Code (NEC) requirement that any AC source must have a 

neutral to ground connection.

• USB Power Port — This power port can supply 5 volts at 2.1A for charging

or powering tablets, e-readers, smartphones, and other small electronic

devices.

• Audible Alarm (internal to the inverter) — When the Audible Alarm makes

a buzzing sound, the inverter senses a low battery condition. The user

should reduce the AC load, charge the battery, and check the DC cable for

excessive losses.

• Remote Switch Connection

Summary of Contents for PURE LINE 3000

Page 1: ...Item No 3810 User s Manual RoHS compliant PURE LINE 3000...

Page 2: ...ates at high efficiency up to 90 that results in long run time and extended battery life compared to other inverters with this level of power output A 2 1A USB power port provides a convenient way to...

Page 3: ...low alarm 10 5V 0 5V DC Battery low shutdown 10 0V 0 5V DC Over voltage shutdown 16 5V 0 5V DC Cooling fan Thermally controlled AC output sockets 3 North American standard USB power port 2 1A 5V Power...

Page 4: ...perate any equipment over 3 000 watts This inverter is designed to operate from a 12 volt DC power source only Do not attempt to connect the inverter to any other power source including any AC power s...

Page 5: ...been activated Shut down the inverter and restart Fault LED Red The RED indicator turns on as the inverter shuts down due to overheating overload under voltage or over voltage Immediately turn off al...

Page 6: ...access terminals Any AC output wiring that is directly connected must comply with US National Electric Code NEC wiring gauge recommendations Facing the front panel the terminals are Left Middle Right...

Page 7: ...ter enclosure ensures personnel safety should a DC cable problem occur During the installation procedure the Ground Terminal is connected either to a vehicle chassis or to the negative DC terminal of...

Page 8: ...damaging either the inverter or the equipment When the red LED indicator is lit the inverter is signaling a fault PLANNING THE INVERTER SYSTEM Any large wattage inverter system requires planning befo...

Page 9: ...ical home use coffee maker draws 500 watts during its brew time of 5 minutes It maintains the temperature of the pot requiring 100 watts Typical use of a microwave oven is only for a few minutes Some...

Page 10: ...rate is will take 20 hours to discharge that battery The terms charged and discharged relate to actual battery voltage This means that the output voltage of a nominal 12 volt battery starts at 13 4 v...

Page 11: ...explosion if the cables that connect to the inverter accidentally short BATTERY BANK DIAGRAM The diagram below shows inverter connections to a battery bank with recommended fuse protection Battery Ba...

Page 12: ...mps ANL fuses are quick acting and sealed so they do not spark when they blow Place fuse no more than one foot from the Positive terminal of the battery Cable length feet 6 8 10 12 14 16 18 20 Fuse Am...

Page 13: ...e Negative black terminal of the battery NOTE Crimp on ring terminals are required on all cable ends The cable ends need to be stripped of insulation for 1 2 inch before crimping on ring terminals Sel...

Page 14: ...inverter The Fault LED may briefly flash This is normal The audible alarm may also sound a short chirp This is also normal 13 When you have confirmed that the appliance to be operated is turned off p...

Page 15: ...cially with weak signals However here are some suggestions that may improve reception Make sure that the television antenna produces a clear signal under normal operating conditions i e plugged into a...

Page 16: ...TrueRated power max output PROBLEM Inverter Shut Down Fault LED Lit Reason Solution Equipment being operated draws too much power Do not use the equipment with this inverter use a higher wattage inver...

Page 17: ...r or weak battery condition Recharge or replace battery Poor or loose cable connection Inspect terminals and tighten all connections Inadequate power being delivered to the inverter or excessive volta...

Reviews: