User’s Manual—Read before using this equipment

12

4. Make sure the Power Switch located on the front panel of the inverter is in

the Off position.

5. Locate the ground lug terminal on the inverter. Connect an insulated 10

gauge copper wire to the terminal. The other end of the ground wire is

connected to a “proper” grounding point. Use the shortest practical length

of wire. Connect this wire to the chassis of your vehicle or to the grounding

system in your boat. In a city, the ground wire can connect to a metal cold

water pipe that goes underground. In remote locations, the ground wire

can be connected to an “earth ground”. This can be an attachment to a foot

long copper clad metal rod driven into the ground. In the unlikely event of

a short circuit, operating the inverter without proper grounding can result in

electrical shock. Do not directly connect this ground wire to the Negative

(black) DC Terminal of the inverter. As an alternative grounding connection,

use the Negative (black) terminal of the battery.

NOTE: Crimp-on ring terminals are required on all cable ends. The cable

ends need to be stripped of insulation for 1/2 inch before crimping on ring

terminals. Select a crimp terminal size to fit the gauge cable and inverter

and battery terminal connectors. After crimping make sure that the cable

connectors are secure on the cables so there are no loose connections.

6. Remove the terminal covers from the inverter. Slide the cable through the

correct terminal cover.

7. Connect the Negative (black) cable end to the inverter terminal and battery

Negative Terminal. Make sure you have good, secure connections.

8. Recheck and make sure the DC cable fuse is installed in the fuse holder.

CAUTION: Making an initial connection between the positive cable end

and the inverter’s positive terminal may cause a spark. This is a normal and

is a result of capacitors in the inverter starting to charge. Because of the

possibility of sparking, it is extremely important that both the inverter and

the battery bank be positioned away from any source of flammable fumes

or gases. Failure to heed this warning can result in fire or explosion. Do not

Summary of Contents for PURE LINE 3000

Page 1: ...Item No 3810 User s Manual RoHS compliant PURE LINE 3000...

Page 2: ...ates at high efficiency up to 90 that results in long run time and extended battery life compared to other inverters with this level of power output A 2 1A USB power port provides a convenient way to...

Page 3: ...low alarm 10 5V 0 5V DC Battery low shutdown 10 0V 0 5V DC Over voltage shutdown 16 5V 0 5V DC Cooling fan Thermally controlled AC output sockets 3 North American standard USB power port 2 1A 5V Power...

Page 4: ...perate any equipment over 3 000 watts This inverter is designed to operate from a 12 volt DC power source only Do not attempt to connect the inverter to any other power source including any AC power s...

Page 5: ...been activated Shut down the inverter and restart Fault LED Red The RED indicator turns on as the inverter shuts down due to overheating overload under voltage or over voltage Immediately turn off al...

Page 6: ...access terminals Any AC output wiring that is directly connected must comply with US National Electric Code NEC wiring gauge recommendations Facing the front panel the terminals are Left Middle Right...

Page 7: ...ter enclosure ensures personnel safety should a DC cable problem occur During the installation procedure the Ground Terminal is connected either to a vehicle chassis or to the negative DC terminal of...

Page 8: ...damaging either the inverter or the equipment When the red LED indicator is lit the inverter is signaling a fault PLANNING THE INVERTER SYSTEM Any large wattage inverter system requires planning befo...

Page 9: ...ical home use coffee maker draws 500 watts during its brew time of 5 minutes It maintains the temperature of the pot requiring 100 watts Typical use of a microwave oven is only for a few minutes Some...

Page 10: ...rate is will take 20 hours to discharge that battery The terms charged and discharged relate to actual battery voltage This means that the output voltage of a nominal 12 volt battery starts at 13 4 v...

Page 11: ...explosion if the cables that connect to the inverter accidentally short BATTERY BANK DIAGRAM The diagram below shows inverter connections to a battery bank with recommended fuse protection Battery Ba...

Page 12: ...mps ANL fuses are quick acting and sealed so they do not spark when they blow Place fuse no more than one foot from the Positive terminal of the battery Cable length feet 6 8 10 12 14 16 18 20 Fuse Am...

Page 13: ...e Negative black terminal of the battery NOTE Crimp on ring terminals are required on all cable ends The cable ends need to be stripped of insulation for 1 2 inch before crimping on ring terminals Sel...

Page 14: ...inverter The Fault LED may briefly flash This is normal The audible alarm may also sound a short chirp This is also normal 13 When you have confirmed that the appliance to be operated is turned off p...

Page 15: ...cially with weak signals However here are some suggestions that may improve reception Make sure that the television antenna produces a clear signal under normal operating conditions i e plugged into a...

Page 16: ...TrueRated power max output PROBLEM Inverter Shut Down Fault LED Lit Reason Solution Equipment being operated draws too much power Do not use the equipment with this inverter use a higher wattage inver...

Page 17: ...r or weak battery condition Recharge or replace battery Poor or loose cable connection Inspect terminals and tighten all connections Inadequate power being delivered to the inverter or excessive volta...

Reviews: