Elite™ 2000W—Pure Sine Inverter
™
by Wagan Tech
®
3
www.wagan.com
Product Features
Front Panel
The Front Panel view shows the inverters ON/OFF Switch, Indicators, AC
Outlets, and Ground Terminal.
• ON/OFF Switch
This switch controls AC output of the inverter.
• The FAULT indicator turns RED as the inverter shuts down because of:
Excessive Temperature, Overload, Under Voltage or Over voltage.
Immediately turn off all AC appliances if the FAULT LED is lit. Allow the
inverter to cool before continuing. Make sure that the ventilation vents
are not blocked.
If an inverter “shutdown” was preceded by a buzzing sound, there may
excessive load, in combination with a low voltage or cable problem.
Observe the Digital Display for low battery voltage. Normal operating
range is 10.5V to 15V DC.
• Digital Display: Press the green Display Mode Selector button to change
current display mode. The Green LEDs will light correspondingly.
• Output Voltage: Displays DC output load.
• Input Voltage: Displays DC input that the inverter senses at its ter-
minals. Low battery, excessive load for the cables can cause a low
voltage reading and inverter shutdown. Low battery is also indicated
when the Audible Alarm sounds.
• Output Power: Shows the “Percent of Load that the inverter can
handle”. If the inverter has excessive load “OVL” will be displayed.
• Audible Alarm (internal to the inverter)
When the audible Alarm makes a buzzing sound, the inverter senses a
low battery condition. The user should reduce the AC load, charge the
battery, and check the DC cable or excessive losses.