Troubleshooting
PROBLEM: Low or No Output Voltage – Fault LED Lit
Reason
Solution
Poor contact with battery, inverter
terminals or DC socket.
Clean terminals thoroughly. Reinstall
and tighten. Clean DC socket with non-
metallic abrasive emery stick.
PROBLEM: No Output Voltage – No LEDs Lit
Reason
Solution
Fuse blown
Check vehicle’s Accessory Socket Fuse
and if blown, replace with the same
type and rating fuse.
PROBLEM: Inverter is Shut Down – Fault LED Lit
Reason
Solution
Battery voltage below 10 volts
Charge or replace battery.
Inverter is too hot (thermal shut down
mode).
• Allow inverter to cool.
• Check for adequate ventilation.
• Reduce the load on the inverter to
rated continuous power output.
PROBLEM: Inverter Shut Down – Fault LED Lit
Reason
Solution
Equipment being operated draws too
much power.
Use a higher wattage inverter or do not
use this equipment.
PROBLEM: Continuous Buzzing Sound
Reason
Solution
Input voltage below 10.5 volts
Keep input voltage above 10.5 volts
Poor or weak battery condition.
Recharge or replace battery.
Poor or loose cable connection
Inspect terminals and tighten all con-
nections.
Inadequate power being delivered to
the inverter or excessive voltage drop.
• Use heavier gauge DC cable.
• Keep cable length as short as
possible.
Disposal/Recycling of Inverter
Electronic products are known to contain materials that are toxic if improperly