Grounding 

 

The power inverter has a lug on the rear panel marked “chassis 
ground”. This is to connect the chassis of the power inverter to the 
ground. The ground terminals in the AC outlets on the front panel of 
the inverters are also connected to the ground lug.  
The chassis ground lug must be connected to the grounding point, 
which will vary depending on where the power inverter is installed. In 
a vehicle, connect the chassis ground to the chassis of the vehicle. 
In a boat, connect to the boat’s grounding systems.  In a fixed 
location, connect the chassis ground lug to earth. 

 

The neutral (common) conductor the power inverter AC output circuit 
is connected to the chassis ground. Therefore, when the chassis is 
connected to the ground, the neutral conductor will also be 
grounded. This conforms to the national electrical code requirements 
the separately derived AC sources (such as inverters and 
generators) have their neutral tied to ground in the same way that 
the neutral conductor from the utility line to ground at AC breaker 
panel. 

 

Caution 

The negative DC input of the power inverter is connected to the 
chassis. Do not install the power inverter in a positive ground DC 
system. As positive ground DC system has the positive terminal of 
the battery connected to the chassis of the vehicle or to the ground 
point. 
 
 

QUICK HOOK UP AND TESTING 

 

If you would like to quickly hook up the power inverter and check its 
performance before going ahead with your installation, please follow 
these guidelines: 
 
1.  Unpack and inspect the power inverter, check to see that the 

power switch in the OFF position. 

 
2.  Connect the cable to the power input terminals on the rear panel of 

power inverter. The red terminal is positive (+) and black terminal is 
negative (-). Connect the cable into the terminals and tighten the wing 
nut to clamp the wires securely. 

 
3.  Connect the cable from the negative terminal of the inverter to the 

negative terminal of the power source. Make a secure connection. 

 

Caution 

Loosely tightened connectors result in excessive voltage drop and may 
cause overheated wires and melted insulation. 

 
4.  Before proceeding further, carefully check that the cable you have just 

connected connects from the negative terminal of inverter to the 
negative output terminal of the power source.  

 
5.  When connecting the inverter directly to your battery terminals, it is 

important to connect with right polarity (connect 

 

from inverter to 

 

of 

battery terminal and connect 

 

from inverter to 

 

of battery terminal) 

 
Warning 

You may observe a spark when you make this connection since 
current may flow to charge capacitors in the power inverter. Do not 
make this connection in the presence of flammable fumes, as 
explosion or fire may result. 

 
6.  Set the power switch to the ON position. Check the meters and 

indicators on the front panels of the inverters. The voltage bar graph 
should indicate 11 to 14 volts, depending on the voltage of the power 
source. If it does not, check your power source and the connections to 
inverter. The other indicators should be off. 

 
7.  Set power inverter switch to the OFF position, the indicator lights may 

blink and the internal alarm may sound momentarily. This is normal. 
Plug the test load into the AC receptacle on the front panel of the 
inverter. Leave the test load switch off. 

Summary of Contents for 3000 Watt

Page 1: ...ation of written instructions furnished Warranty Disclaimers This warranty is in lieu of all warranties expressed or implied and no representative or person is authorized to assume any other liability...

Page 2: ...nces that use AC power such as TVs VCRs portable computers power tools and lights for emergency or camping use It provides a continuous output of up to 3000 watts REAR VIEW a Ventilation window Do not...

Page 3: ...oration Printed in China 3 Front View Warning Operation of the inverter without a proper ground connection may result in an electrical safety hazard BASIC OPERATION Use the right operating voltage for...

Page 4: ...ng requirements a Dry Do not allow water to drip or splash onto the inverter b Cool Ambient air temperature should be between 0 C and 40 C the cooler the better c Ventilation Allow at least 2 inches o...

Page 5: ...STING If you would like to quickly hook up the power inverter and check its performance before going ahead with your installation please follow these guidelines 1 Unpack and inspect the power inverter...

Page 6: ...power inverter and disconnect all appliances from inverter and disconnect the inverter from power supply The beeping sound is simply the low battery warning which indicates that the voltage of the ba...

Page 7: ...installed properly You need to contact the RV or auto experts for some instructions SAFETY PRECAUTION Do not open the case of the inverter The high voltage inside the unit is the same type of power as...

Page 8: ...ow battery drained Overload Short Circuit Protection the inverter automatically turns itself off if the connected load is too high or if it shorts Fuse the inverter comes with fuse s already installed...

Reviews: