Neutral
Neutral
Hot
Hot
Ground
Ground
Hot
Sense
Hot
Hot
Sense
Hot
Household
Inverter
User’s Manual—Please read before using this equipment.
7
This sense line action is a safety function similar to GFCI. However, GFCI is a mechanical
interruption, not an electronic shut down. GFCI and the sense line can activate with a
leakage of 5 mA or less. Automatic shutdown is an important safety feature, especially in
applications near water.
Note that some older appliance power cords or outlets may have the ground pin connected
to the “neutral” connection. This connection will keep the inverter in a shut-down condition.
The appliance ground connection must be isolated from the neutral plug connection for the
inverter to operate.
CAUTION: CONNECTING THE “SENSE LINE” TO GROUND OR TO EITHER “HOT”
TERMINAL WILL KEEP THE INVERTER IN A SHUTDOWN CONDITION
Terminal and Outlet Diagram