User’s Manual—Please read before using this equipment.
17
Reason
Solution
Inverter is too hot (thermal shut down mode) Allow inverter to cool
Check for adequate ventilation.
Reduce the load on the inverter to rated
continuous power output
Unit may be defective
See warranty and call customer service
PROBLEM: TV interference
Reason
Solution
Electrical interference from the inverter
Add a ferrite data line filter on to the TV
power cord
PROBLEM: Low battery alarm on all the time
Reason
Solution
Input voltage below 10.5 volts
Keep input voltage above 10.5 volts to
maintain regulation
Poor or weak battery condition
Recharge or replace battery
Inadequate power being delivered to the
inverter or excessive voltage drop
Use lower gauge wire
Keep wire length as short as possible
PROBLEM: TV does not work
Reason
Solution
TV does not turn on
Contact TV manufacture to see if the TV is
compatible with a modified sine wave
© 2008 Wagan Corporation.
All Rights Reserved.
Wagan and wagan.com are trademarks used by Wagan Corporation.
Summary of Contents for 2007-2
Page 1: ...Item no 20072 User s Manual 3000 Watt AC Inverter R ...