background image

WAFER GSM-KEY REMOTE CONTROL UNIT 

http://www.waferstar.com 

9.

 

Log Tab 

10.

 

Phone numbers Tab – Add regular phone numbers 200 

11.

 

Special phone numbers Tab – Add special phone numbers 750 

12.

 

Alarm Phone numbers Tab – Add alarm phone numbers 5 

13.

 

Miscellaneous Tab 

 
The following compand is used in the GSM-KEY : 

#PWD

:  

 

Password 

#CAP

 

  Change 

password 

#WHL

:   

 

White List (add or remove numbers) 

#GOT

  Gate 

pulse 

time 

#ALARM

:    

Alarm information setting 

#MODE:    

Relay mode 

#CSQ

 

  Check 

Signal 

Quality 

#SCA:   

 

Set service center address 

#STATUS

:   

Check status 

#OUT

:    

 

Use the SMS to control the switch to ON or OFF 

 
 
Once you issue a command with an SMS, you will receive a confirmation SMS with OK 

if everything is correct or Err if there is an Error. 
 

GSM-KEY SMS COMMAND LIST: 

#PWD Password.  

This command must always come first 6 digits as a password. 
The standard default one, when the device comes from the factory, is 123456. 
We suggest that you change it, using the #CAP command. 
In all the following examples we will use 123456 as an example of password. 

 
#CAP Change Password
.  

Use this command to change the password with a new one that you will chose for your device 
( don't forget it or you will have to send the unit back to us to reset it, and this has a cost ) 
The #CAP command must be issued 2 times to be sure you don't digit a wrong one. 
OF course it must be preceded by the old password. 
For example, to change the password 123456 into the new password 333444 you need to send the 
following SMS: 

#PWD123456#CAP333444#CAP333444 

Acknowledge SMS: PWD SETUP OK   
If you wrote correctly, or an Error message if you made a mistake. 
If the old password is error,then conformation would be :

 Error Old Password

 

If you input two different new password,then reply would be :

 Error New Password,Please Check the 

input again

 

 

Summary of Contents for GSM-KEY-ADC200

Page 1: ...WAFER GSM KEY REMOTE CONTROL UNIT http www waferstar com GSM KEY ADC200 MANUAL ADC200 VERSION 5 0 SHANGHAI WAFER MICROELECTRONICS CO LTD ...

Page 2: ...eject the call so there will be no charge at least with today s charging procedures and click the relay momentarily Also GSM KEY has two alarm input port for the security detection including the intruder detection alarm and gate problem alarm CONNECTOR DESCRIPTION ADVANTAGES OF WAFER GSM KEY ˇ 200 Regular User Numbers memory ˇ SHL50 PHL50 QHL50 total 150 Special Numbers memory for time zone ˇ 5 Al...

Page 3: ...ore inserting it in the unit GSM KEY also comes with additional 2 Input The inputs can be used to generate alarms when triggered For examples you can can connect the saftey beam output to the GSM KEY Alarm1 and Alarm2 input Please read this entire manual before installation Note z Take EXTREME care with the Voltage Power supply at AC DC12 24V z Mustn t suppy the 110V or 220V to this device that wo...

Page 4: ...ow wire picture is to show how to connect the cable to the PC program connector with the Program adapter Please connect it in the right direction with the picture GSM KEY PC Program Software interface 1 Setting and Log page switch 2 Open saved file 3 Save units phone numbers in your computer for future changes 4 Save in a new file name 5 Communitcaton selection Com port configuration 6 Connect to ...

Page 5: ... 6 digits as a password The standard default one when the device comes from the factory is 123456 We suggest that you change it using the CAP command In all the following examples we will use 123456 as an example of password CAP Change Password Use this command to change the password with a new one that you will chose for your device don t forget it or you will have to send the unit back to us to ...

Page 6: ...country code 852 If your number has only 9 digits or less it is not a problem The important thing is that you don t exceed 10 digits To check which is the number in a place of the list PWD123456 WHL001 Acknowledge WHL001 IS 61143815 OK To erase a number PWD123456 WHL001 0000000 or you can write over it another number you wish to add Acknowledge WHL001 SET TO 00000000 List All numbers in the List P...

Page 7: ...ed to setup the GOT timer number This command is useful in case you need to keep the button pressed longer The standard time is 0 3 seconds 300 ms You can change it with the GOT command The syntax of the command is the following PWD123456 GOT500 Acknowledge DELAY TIME SET TO 0500MS With the above command the opening time has been set to 500 ms 0 5 seconds You can check what the current pulse time ...

Page 8: ...DI1 XXXXXX UDI2 XXXXXX Acknowledge UDI1 XXXXXX DI2 XXXXXX OKAY When the Alarm input is triggered then will send the SMS you already setted with this UDI command CSQ Check GSM signal quality This command is useful to see what is the GSM network signal level your GSM KEY is receiving It ranges from 0 to 32 if it is 0 we doubt it will ever answer You should have a signal above 12 to be sure of being ...

Page 9: ...ledge as OUT1 ON okay PWD123456 OUT1 OFF This is used to control the outpt switch to OFF Your will receive the Acknowledge as OUT1 OFF okay PC Software interface Software language select Select the right language according to your county wafer will update the language step by setp When Distributor need to support your local language please contact wafer company COM Port parameters config interface...

Page 10: ...nly for the GSM RFKEY device And each device have a special ID number 3 GSM modem program mode GSM modem program adapter Check the select box of the use modem For this mode that is to use the SMS to program the remote GSM KEY device So you need to input the Receive expired time and also need to input the GSM KEY device SIM card number into the unit phone number text box For this mode you also need...

Page 11: ...ROL UNIT http www waferstar com GSM Modem program adapter Phone Numbers Setting interface Before download the phone numbers you need to SET the index to red color then push the button Download All Phones Special Phones Setting ...

Page 12: ...WAFER GSM KEY REMOTE CONTROL UNIT http www waferstar com Alarm Phone Numbers Setting Log Interface ...

Page 13: ...WAFER GSM KEY REMOTE CONTROL UNIT http www waferstar com Miscellanelous Parameters Setting Page Unit Info That is showing the Device edition of the design you don t need to change it ...

Page 14: ... That is used to setup the working mode Relay Status That is used to test the device through ON or OFF the on board relay Alarm That is used to setup the alarm mode of the two alarm channel Alarm content That is used to setup the alarm SMS content Note 1 Gate delay cann t be setup to 0 then when you call the device that relay output would not work 2 You shouldnot change the BAND selection if you a...

Page 15: ...rt can be find in the computer device manager or not Our device has no relationship with the COM port can be find or not If you use the USB to RS232 adapter should check the drive is properly installed or not What type of the USB to COM port adapter should order to work with GSM KEY That would be better to order WAFER USB adapter Order the good quality USB adapter with FT232 chip inside GSM KEY do...

Page 16: ...of WEIFU GSM Modules For further information and queries kindly contact Email wafer waferstar com Web www waferstar com Tel 0086 21 51870528 Also accessible via our online Service Skype wafer service If you need any sample order please check our online store Http www wafer shopping com Copyright 2008 WEFU GSM V201312 V5 0 ...

Reviews: