WAFER GSM-KEY REMOTE CONTROL UNIT
http://www.waferstar.com
9.
Log Tab
10.
Phone numbers Tab – Add regular phone numbers 200
11.
Special phone numbers Tab – Add special phone numbers 750
12.
Alarm Phone numbers Tab – Add alarm phone numbers 5
13.
Miscellaneous Tab
The following compand is used in the GSM-KEY :
#PWD
:
Password
#CAP
:
Change
password
#WHL
:
White List (add or remove numbers)
#GOT
:
Gate
pulse
time
#ALARM
:
Alarm information setting
#MODE:
Relay mode
#CSQ
:
Check
Signal
Quality
#SCA:
Set service center address
#STATUS
:
Check status
#OUT
:
Use the SMS to control the switch to ON or OFF
Once you issue a command with an SMS, you will receive a confirmation SMS with OK
if everything is correct or Err if there is an Error.
GSM-KEY SMS COMMAND LIST:
#PWD Password.
This command must always come first 6 digits as a password.
The standard default one, when the device comes from the factory, is 123456.
We suggest that you change it, using the #CAP command.
In all the following examples we will use 123456 as an example of password.
#CAP Change Password.
Use this command to change the password with a new one that you will chose for your device
( don't forget it or you will have to send the unit back to us to reset it, and this has a cost )
The #CAP command must be issued 2 times to be sure you don't digit a wrong one.
OF course it must be preceded by the old password.
For example, to change the password 123456 into the new password 333444 you need to send the
following SMS:
#PWD123456#CAP333444#CAP333444
Acknowledge SMS: PWD SETUP OK
If you wrote correctly, or an Error message if you made a mistake.
If the old password is error,then conformation would be :
Error Old Password
If you input two different new password,then reply would be :
Error New Password,Please Check the
input again