Mounting the gas detector
Note the following information when selecting a location to mount the gas detector:
z
Note the length of the cable.
z
The gas detector should be mounted in the vicinity of the sleeping area at the height
of the mattress.
➤
Select a suitable installation location.
Caution!
Before making any drill holes, ensure that no electrical cables or other parts of
the vehicle can be damaged by drilling.
➤
Hold the mounting panel on the chosen location and mark the two drill holes (
5
,
page 5).
➤
Screw the mounting panel tight with the two screws (
6
, page 5).
➤
Insert the gas detector on the mounting panel (
7
, page 5).
➤
Insert the plug of the gas detector in the socket of your 12/24 V DC voltage supply.
✓
The green LED on the gas detector (
8
1, page 5) flashes for approx. 10 min. The
sensor is then brought to the operating temperature.
When the green LED glows constantly, the gas detector is ready for operation.
8
Connecting the gas detector
8.1
As a single device
If you use the MSG-150 as a single device, you can either
z
Switch it on with the 12/24 V plug.
z
Switch it on with the RV-AMP-SW additional switch (accessory), if there is no 12/24 V
socket in the sleeping area.
Connecting the MSG-150 with a 12/24 V plug
➤
Insert the 12/24 V plug into a socket with a constant 12/24 V supply.
This socket should be connected to the battery.
✓
An acoustic signal sounds and the green LED (
8
1, page 5) flashes for approx 10
minutes.
During this time the MSG-150 conducts a system test and the sensor is brought to
operating temperature.