Technical description
ECL-75, ECL-102
36
The air conditioner compressor is switched off in this way. The light system now charges
the starter battery. If the vehicle has a connecting cable between the two batteries, the
additional battery is also charged.
If the charging voltage of the light system UD+ reaches the set voltage value Ue again,
the power relay and the control relay switch on again. The air conditioner compressor
starts again.
If the vehicle engine is not switched on (UD+ = 0 V), relay contact 30/87 (Batt. I/Batt. II)
is opened and relay contact I2, I3 is closed. The air conditioner can be operated and only
takes power from the additional battery. If the battery voltage falls below Ubatt = 10.5 V,
the inverter switches off.
6.4
DC kit 2 with Dometic B2200 / B1600 Plus
z
Circuit diagram, see page 6
z
Roof air conditioner: Dometic B2200 / B1600 Plus
z
Charging current distributor: ECL-102
z
Inverter: ECW-012VS
The light system voltage UD+ is measured. If this voltage exceeds a variable voltage
value Ue (12.5 V - 14.0 V), the relay contact 30/87 (Batt. I/Batt. II) of the power relay is
closed. The starter battery and the additional battery are therefore connected in parallel
with low resistance and are charged together by the light system.
Contact I5/I2 is opened with UD+ > Ue and this switches the air conditioner on.
If the light system voltage falls below a variable threshold value Ua (10.5 V - 12.5 V), due
to an increased load because of the air conditioner, relay contact 30/87 (Batt. I/Batt. II) is
closed. Relay contact I5/I2, which interrupts the connection between the on/off cable and
the air conditioner, is opened.
The air conditioner compressor is switched off in this way. The light system now charges
the starter battery. If the vehicle has a connecting cable between the two batteries, the
additional battery is also charged.
If the charging voltage of the light system UD+ reaches the set voltage value Ue again,
the power relay and the control relay switch on again. The air conditioner compressor
starts again.
If the vehicle engine is not switched on (UD+ = 0 V), relay contact 30/87 (Batt. I/Batt. II)
and relay contact I5/I2 are opened. The air conditioner can be operated and only takes
power from the additional battery. If the battery voltage falls below Ubatt = 10.5 V, the
inverter switches off.
6.5
DC kit 3 with Dometic CA1000 / CA2500
z
Circuit diagram, see page 7
z
Roof air conditioner: Dometic CA1000 / CA2500
z
Charging current distributor: ECL-102
z
Inverter: SinePower SP1500 (item no. MSK1500-012)
_ECL-75_102.book Seite 36 Donnerstag, 6. Mai 2010 4:43 16
Summary of Contents for ECL-102
Page 10: ...ECL 75 ECL 102 10 8 9 _ECL 75_102 book Seite 10 Donnerstag 6 Mai 2010 4 43 16...
Page 11: ...ECL 75 ECL 102 11 10 11 _ECL 75_102 book Seite 11 Donnerstag 6 Mai 2010 4 43 16...
Page 178: ..._ECL 75_102 book Seite 184 Donnerstag 6 Mai 2010 4 43 16...
Page 179: ..._ECL 75_102 book Seite 185 Donnerstag 6 Mai 2010 4 43 16...