Inverter (only for the CB-1200-AC/DC)
CB-1200
54
8.7
Troubleshooting
The LED is lit green in the control panel of the fresh air cooling system
when the device is working properly.
If a fault occurs, the LED will be lit orange. This is due to one of the
following malfunctions:
Possible errors
Cause
Troubleshooting
No inverter output
voltage
The battery voltage is below
9.9 V ± 0.2 V.
Charge the battery
(start the engine).
The inverter is overheated.
Switch off the consumers.
Allow the inverter to cool down.
Provide better ventilation.
The fuse in the device is defective. Have an electrician replace the
fuse in the inverter.
Warning signal
during operation
The battery voltage is below
10.5 V ± 0.2 V.
Charge the battery
(start the engine).
No output voltage
in mains operation
(priority mode)
Fuse 6.3 AT outside in the
insulated socket is defective (front).
Replace the fuse 6.3 AT