37
Technical data
CoolAir
6.3.6
Menu level 5: Temperature unit display
The system can display the room temperature in °C or °F. This parameter
can be configured:
➤
Start configuration mode (see Chapter "Starting and ending configu-
ration mode" on page 33).
✓
The first digit of the display (fig.
7
on page 5, item 5) shows the menu
level and the second and third show the parameter which can be set.
➤
Press the
+
(fig.
7
on page 5, item 6) four times to switch to menu
level
5
.
➤
Press the
Operating Mode
button (fig.
7
on page 5, item 4) to
change the parameters.
✓
The digits in the display flash until the parameter you entered is con-
firmed.
➤
Use the
+
and
–
buttons (fig.
7
on page 5, item 6 and 7) to select the
temperature unit that the system should display.
➤
Press the
Operating Mode
button (fig.
7
on page 5, item 4) to con-
firm your entry.
✓
The set value is saved and is then used when the unit is restarted.
✓
You are now in menu level 5 again and can use the
+
and
–
buttons to
switch between menu levels.
7
Technical data
Versions, technical modifications and delivery options reserved.
Air conditioning roof unit
CoolAir CA850S
Item number
9100100027
Cooling capacity:
850 W
Rated input voltage:
24 V DC
Input voltage range:
20 V DC – 30 V DC
Current consumption:
12 – 22 A
Low voltage shutdown:
Configurable (see Chapter "Menu level 2: Low
voltage cut-off" on page 34)
Dimensions (L x
B x
H in mm)
(height above vehicle roof):
635 x 830 x 179
Weight:
approx. 21 kg
CA-850S_EBA.book Seite 37 Mittwoch, 8. September 2010 7:31 19
Summary of Contents for Coolair CA850S
Page 3: ...3 CoolAir 179 276 353 1 830 2 1 3 CA 850S_EBA book Seite 3 Mittwoch 8 September 2010 7 31 19...
Page 4: ...CoolAir 4 4 1 2 3 4 7 6 5 5 CA 850S_EBA book Seite 4 Mittwoch 8 September 2010 7 31 19...
Page 5: ...5 CoolAir 6 1 6 2 3 4 5 8 7 7 CA 850S_EBA book Seite 5 Mittwoch 8 September 2010 7 31 19...