ColdMachine
Installing the cooling unit
35
Caution!
Carefully insulate and seal off the wall openings after installation to
prevent moisture penetration.
For cooling units with valve couplings:
Cut out a hole with a diameter of at least 30 mm (
c
, page 7) for the cooling
lines. To do this, use a circular cutter.
Caution!
Never bend the connecting line between the vaporiser and the unit.
The minimum bending radius is 25 mm.
6.2
Installing the cooling unit
It is important to select the proper location for setting up the unit. To ensure
trouble-free operation, please note the following points:
z
Set up the cooling unit in a dry, sheltered place. Avoid placing it near heat
sources such as radiators, gas ovens or hot water pipes. Do not place in
direct sunlight.
z
On a boat, install the cooling unit, if possible, below the waterline.
sw
Black
No. in
9
,
page 6
Explanation
1
Connection cable
gr/ge
Green/yellow
bl
Blue
br
Brown
sw
Black
No. in
0
,
page 6
Explanation
1
Drip tray
No. in
8
,
page 5
Explanation
_coldmachine.book Seite 35 Dienstag, 31. Mai 2005 3:15 15