The display shows
“
Error 03
”
No data is coming from the
refrigerant scale.
Check the scale.
The display shows
“
Error 04
”
It is not possible to lower the
pressure when flushing takes
place.
Check air conditioner and
connections for leaks, con-
strictions and ice build-up.
Check pressure transducer
calibration.
The display shows
“
Error 09
”
During the flushing process,
no pressure could be ascer-
tained at the low pressure
connection of the air condi-
tioning service unit.
Connect low pressure hose
to the flush container and
open valve.
The display shows
“Error 10”
During the software test, the
compressor failed to reduce
the internal pressure suffi-
ciently.
Residual pressure on the
pressure gauges?
Check pressure transducer
calibration.
Check internal bottle pres-
sure.
Check the compressor and
the corresponding solenoid
valves.
The display shows
“Error 12
”
It was not possible to remove
any refrigerant from the inter-
nal tank during the software
test.
Check pressure transducer
calibration.
Check whether the tank
valve on the internal tank is
open.
Is the ambient temperature
above 10 °C?
The display shows
“Error 52
”
No USB stick was found/rec-
ognised
Insert the USB stick.
Make sure that USB stick has
been formatted with the
FAT32 file system.
The display shows
“Error 60
”
During the hybrid service
(flushing the service hoses
with hybrid oil), a vacuum
could not be achieved.
Are the service hoses con-
nected to the hybrid flush
container?
Is the hybrid flush container
fitted the right way round?
Check the connections for
leaks.
Problem
Cause
Remedy
Summary of Contents for AirConServiceCenter ASC 3500 G LE
Page 2: ......
Page 242: ...RU ASC2500G ASC3500G 242 1 2 A I ENTER Short selection 1 2 3 1 2 3 1 248 249 8 A E...
Page 245: ...RU 245 ASC2500G ASC3500G 2 2 AirConServiceCenter 230 50 2 3...
Page 255: ...RU 255 ASC2500G ASC3500G 7 7 1 21 18 19 20 2 21 3 256 20 19 18 21...
Page 263: ...RU 263 ASC2500G ASC3500G I 8 2 2 1 STOP ENTER USER CODE WRONG CODE Max Mustermann...
Page 280: ...RU ASC2500G ASC3500G 280 5 21 18 19 20 ENTER 6 18 20 19 21 7 STOP 20 19 18 21...
Page 290: ...RU ASC2500G ASC3500G 290 9 9 USB USB I AirConServiceCenter 1 USB 2 USB USB 16 USB FAT32 16...
Page 292: ...RU ASC2500G ASC3500G 292 9 10 I 20 6 1 21 20 2 M N 6 20 21 M N...
Page 293: ...RU 293 ASC2500G ASC3500G 3 O P 4 N Q 5 9 11 11 12 13 14 AirConServiceCenter P O Q N...
Page 294: ...RU ASC2500G ASC3500G 294 10 10 1 I 10 2 10 3 AirConServiceCenter M...
Page 297: ...RU 297 ASC2500G ASC3500G Error 01 Error 02 Error 03 Error 04 Error 09 Error 10 Error 12 10 C...
Page 298: ...RU ASC2500G ASC3500G 298 Error 52 USB USB USB FAT32 Error 60 Error 61...