EN
Problem
Possible cause
Suggested remedy
The display shows
Error 52
No USB flash drive was found/recog-
nised.
Insert the USB flash drive.
Ensure that the USB flash flash
drive has been formatted with the
FAT32 file system.
The display shows
Error 60
During the hybrid service (flushing the
service hoses with hybrid oil), a vacu-
um could not be achieved.
Are the service hoses connected to
the hybrid flush container?
Is the hybrid flush container fitted
the right way round?
Check the connections for leaks.
The display shows
Error 61
Pressure increase during the hybrid
service (flushing the service hoses with
hybrid oil).
Are the service hoses connected to
the hybrid flush container?
Is the hybrid flush container fitted
the right way round?
Are the service couplings open?
The display shows
Error G1
A connection to the analysis module
could not be made.
Check the connections.
Are the LEDs on the module acti-
vated?
The display shows
Error 00001
The readings are unstable.
Keep possible electrical sources
of interference, such as mobile
phones or welding equipment, away
from the device.
The display shows
Error 00002
The readings are excessively high.
Keep possible electrical sources
of interference, such as mobile
phones or welding equipment, away
from the device.
The display shows
Error 00003
Calibration with the ambient air failed.
Ensure the device is adequately
ventilated.
Leave any leaking refrigerant to
drain off.
The display shows
Error 00004
The device is operating outside the rec-
ommended temperature range.
Only use the device in tempera-
ture-controlled rooms (10 °C – 45
°C).
Ensure sufficient ventilation.
The display shows
Error 00001
The refrigerant sample has a very high
content of air or the amount of refriger-
ant was too low for testing.
Ensure that there is enough refrig-
erant pressure.
Ensure that all the hoses are con-
nected, not kinked and free of oil.
16 Disposal
NOTICE! Protect the environment
All operating fluids and components may only be disposed of by qualified personnel in accordance with
national regulations.
Disposing of used fluids
•
Used oil is hazardous waste.
•
Do not mix used oil with other fluids.
•
Prior to disposal keep used oil in suitable containers.
Disposing of packaging material
•
Dispose of the cardboard packaging material with other waste paper.
•
Dispose of plastic packaging material with other recyclable waste.
Disposal of the old A/C service unit
•
If you wish to dispose of the A/C service unit, first completely drain it of all liquids and dispose of them accord-
ing to national regulations.
38
Summary of Contents for 9103303105
Page 9: ...EN 16 USB port 9 ...
Page 41: ...EN 17 1 Flowchart ASC6300 G Legend 41 ...
Page 44: ...EN 17 2 Flowchart ASC6400 G Legend 44 ...
Page 47: ...EN 17 3 Circuit diagram ASC6300 G 47 ...
Page 48: ...EN 48 ...
Page 49: ...EN 17 4 Circuit diagram ASC6400 G 49 ...
Page 50: ...EN 50 ...
Page 58: ...FR 16 Port USB 58 ...
Page 92: ...FR 17 1 Organigramme ASC6300 G Légende 92 ...
Page 95: ...FR 17 2 Organigramme ASC6400 G Légende 95 ...
Page 98: ...FR 17 3 Schéma électrique ASC6300 G 98 ...
Page 99: ...FR 99 ...
Page 100: ...FR 17 4 Schéma électrique ASC6400 G 100 ...
Page 101: ...FR 101 ...
Page 109: ...DE 16 USB Anschluss 109 ...
Page 142: ...DE 17 1 Flussdiagramm ASC6300 G Legende 142 ...
Page 145: ...DE 17 2 Flussdiagramm ASC6400 G Legende 145 ...
Page 148: ...DE 17 3 Schaltplan ASC6300 G 148 ...
Page 149: ...DE 149 ...
Page 150: ...DE 17 4 Schaltplan ASC6400 G 150 ...
Page 151: ...DE 151 ...
Page 159: ...RU 16 USB порт 159 ...
Page 192: ...RU 17 1 Блок схема ASC6300 G Пояснения 192 ...
Page 195: ...RU 17 2 Блок схема ASC6400 G Пояснения 195 ...
Page 198: ...RU 17 3 Схема соединений ASC6300 G 198 ...
Page 199: ...RU 199 ...
Page 200: ...RU 17 4 Схема соединений ASC6400 G 200 ...
Page 201: ...RU 201 ...
Page 209: ...ES 16 Conexión USB 209 ...
Page 244: ...ES 17 1 Diagrama de flujo ASC6300 G Leyenda 244 ...
Page 247: ...ES 17 2 Diagrama de flujo ASC6400 G Leyenda 247 ...
Page 250: ...ES 17 3 Esquema de conexiones ASC6300 G 250 ...
Page 251: ...ES 251 ...
Page 252: ...ES 17 4 Esquema de conexiones ASC6400 G 252 ...
Page 253: ...ES 253 ...
Page 254: ...4445103554 2022 11 30 ...