Tables
Fuses
182
BA RC50_RC70 en 00
5.03
Fuses
WARNING
Fire in the machine electrical system!
Serious injuries or death or material damage as a result of fire caused by using fuses not meeting
specifications.
■
Only use fuses specified by the manufacturer (not fuses with a higher amperage).
■
Do not bridge fuses.
N
O
T
E
The fuse assignment indicates a fully equipped machine. Depending on the machine
configuration (special attachments), slots are correspondingly free or occupied by fuses.
Please follow the fuse assignment shown on the adhesive label in the engine compartment.
5
4
1, 2, 3
[1]
Main fuses
[2]
Alternator D+
[3]
Battery isolating switch
[4]
Central electrical system
[5]
Driver's cab
5.03.01
Engine compartment
[1] Main fuses
Component
Fuse assignment
Fuse
F01.1
Alternator B+
100 A
F01.2
Cold starting device
100 A
F01.3
On-board power supply (terminal 30)
100 A
F01.4
Solenoid switch for starter motor
30 A
[2] Fuse, alternator D+
Component
Fuse assignment
Fuse
F02
Alternator D+
5 A