Operation
PS (3-Phase) Series
wc_tx000131gb.fm
22
Water Level During Operation
Do not operate the pump below Continuous Running Water Level (a),
as doing so will damage the pump, causing current leakage and
electrical shock.
The table below shows the water level during operation by output.
Make sure that the water level will not be under these levels.
See Graphic: wc_gr000335
Model
Continuous Running Water Level
PS2 1503
PS2 2203
PS3 1503
PS3 2203
120 mm (4¾”)
PS2 3703
PS4 3703
PS4 5503
PS3 3703
PS3 5503
150 mm (6”)
PS4 7503HH
PS4 11003HH
PS4 7503HF
PS4 11003HF
190 mm (7½”)
CAUTION
a
wc_gr000335