![Wacker Neuson PS2 1503 Operator'S Manual Download Page 18](http://html1.mh-extra.com/html/wacker-neuson/ps2-1503/ps2-1503_operators-manual_3213106018.webp)
Operation
PS (3-Phase) Series
wc_tx000131gb.fm
16
4.4
Electrical Wiring
Performing electrical wiring
Electrical wiring should be performed by a qualified person in accord
with all applicable regulations. Failure to observe this precaution not
only risks breaking the law but is extremely dangerous.
Incorrect wiring can lead to current leakage, electrical shock or fire.
ALWAYS make sure the pump is equipped with the specified overload
protectors and fuses or breakers, so as to prevent electrical shock from
a current leak or pump malfunction.
Operate within the capacity of the power supply and wiring.
Grounding
DO NOT use the pump without first grounding it properly. Failure to
ground it can lead to electrical shock from a current leak or pump
malfunction.
DO NOT attach the grounding wire to a gas pipe, water pipe, lightning
arrestor or telephone grounding wire. Improper grounding can result in
electrical shock.
Cable Assembly
If it is necessary to extend the cable assembly, use a core size equal
to or larger than the original. This is necessary not only for avoiding a
performance drop, but to prevent cable overheating which can result in
fire, electrical leakage or electrical shock.
If a cable with cut insulation or other damage is submerged in the
water, there is a danger of damage to the pump, electrical leakage,
electrical shock, or fire.
Be careful not to let the cable assembly be cut or become twisted. This
may result in damage to the pump, electrical leakage, electrical shock,
or fire.
If it is necessary to submerge the connection wires of the cable
assembly in water, first seal the wires completely in a molded
protective sleeve, to prevent electrical leakage, electrical shock, or fire.
DO NOT allow the cable assembly wires or power supply plug to
become wet.
Make sure the cable does not become excessively bent or twisted, and
does not rub against a structure in a way that might damage it.
If used in a deep-well installation, the cable assembly should be
secured every twenty feet.
WARNING
WARNING
CAUTION
CAUTION
Summary of Contents for PS2 1503
Page 1: ...Pump PS 3 Phase Series OPERATOR S MANUAL 0154623en 002 0107 0 1 5 4 6 2 3 E N...
Page 2: ......
Page 4: ...Table of Contents PS 3 Phase Series wc_bo0154623002enTOC fm 2...
Page 38: ......
Page 39: ......
Page 40: ......
Page 41: ......
Page 42: ......
Page 43: ......
Page 44: ......
Page 45: ......
Page 46: ......
Page 47: ......
Page 48: ......
Page 49: ......