PG 2A / 3A
Maintenance
wc_tx000178gb.fm
33
5.9
Cleaning the Sediment Cup
See Graphic: wc_gr000029
5.9.1
Turn the fuel valve off.
5.9.2
Remove the sediment cup
(a)
and the O-ring
(b)
.
5.9.3
Wash both thoroughly in a nonflammable solvent. Dry and reinstall
them.
5.9.4
Turn the fuel valve on and check for leaks.
Summary of Contents for PG 3A
Page 1: ...Operator s Manual Pump PG 3A 5000184874 08 0511 5 0 0 0 1 8 4 8 7 4 EN...
Page 6: ......
Page 16: ...Labels PG 3A 16 wc_si000519gb fm 2 Labels 2 1 Label Locations wc_gr000833 A C D E G H F B...
Page 40: ...Emission Control Systems Information and Warranty 40 wc_tx001753gb fm...
Page 41: ......
Page 42: ......
Page 43: ......
Page 44: ......
Page 45: ......
Page 46: ......
Page 47: ......
Page 48: ......
Page 49: ......
Page 50: ......
Page 51: ......
Page 52: ......
Page 53: ......