Maintenance
PG 2A / 3A
28
wc_tx000178gb.fm
5.4
Adjusting the Impeller Clearance
See Graphic: wc_gr000838
If it is necessary to replace impeller or volute, be sure clearance
between impeller and volute is adjusted correctly. The impeller
(a)
should be as close to the volute
(b)
as possible without rubbing against
it. Clearance is adjusted by adding or removing shims
(c)
from behind
impeller. To adjust the clearance do the following:
5.4.1
Remove pump housing but do not remove impeller.
5.4.2
Measure the distance
(d)
of volute.
5.4.3
Measure the distance
(e)
of impeller.
5.4.4
Subtract the distance
(e)
from
(d)
.
(d) - (e) = (f)
clearance.
5.4.5
The clearance between the volute and the impeller should be 0.3 mm
(0.012 in.) to 0.7 mm (0.028 in.). Adjust the distance by removing the
impeller and adding shims as needed.
Each shim measures 0.3 mm (0.012 in.).
As the impeller wears down, additional shims may be required to
maintain the clearance between the impeller and the volute. Check the
clearance whenever the mechanical seal
(g)
, impeller, volute, or rear
flange plate are replaced.
b
d
e
g
c
a
f
wc_gr000838
Summary of Contents for PG 3A
Page 1: ...Operator s Manual Pump PG 3A 5000184874 08 0511 5 0 0 0 1 8 4 8 7 4 EN...
Page 6: ......
Page 16: ...Labels PG 3A 16 wc_si000519gb fm 2 Labels 2 1 Label Locations wc_gr000833 A C D E G H F B...
Page 40: ...Emission Control Systems Information and Warranty 40 wc_tx001753gb fm...
Page 41: ......
Page 42: ......
Page 43: ......
Page 44: ......
Page 45: ......
Page 46: ......
Page 47: ......
Page 48: ......
Page 49: ......
Page 50: ......
Page 51: ......
Page 52: ......
Page 53: ......