Operation
7.10 Machine Monitoring
66
Operator’s Manual | LTV 4L/6L | 5100065071 | 02/2023 | [en-US]
5.
Allow the engine to warm up before operating the lights.
Operating the lights
1.
Turn on the main circuit breaker
(1)
.
1
2
4
5
6
3
Fig. 38: Starting, operating, and stopping controls
2.
Turn on individual circuit breakers
(3)
one at a time.
Notes
• Metal halide floodlights require a warm-up time of 5–15 minutes before
they reach full brightness.
• After turning the lights off, a cool-down time of 10 minutes is necessary
before they can be turned on again.
Stopping the machine
NOTICE
Failure to turn off lights may cause damage to the electrical system.
►
Turn off the lights before stopping the engine.
1.
Disconnect all loads from the machine.
2.
Turn the circuit breakers
(1)
off.
3.
Press the Stop button
(5)
to de-energize the fuel solenoid.
7.10
Machine Monitoring
Engine and generator information is displayed on the LCD panel. The user
can scroll through the screens to monitor machine parameters.