IREN
Maintenance
25
Checking the machine
f
Check all machine parts for damage.
Machines with ON/OFF switch:
f
Check the tightness of the switch diaphragm.
Check wear dimensions of the vibrator head
Wear dimensions:
Minimum diameter of lower tube øL
L
Minimum diameter of vibrator head øL
Length of vibrator head L
L
Wear is highest at the immersed end of the vibrator head.
Dimensions in bold are wear dimensions.
Dimensions in brackets are original dimensions of new machines.
Let the lower tube be exchanged by your WACKER contact if the wear dimen-
sions are reached at a certain point.
Changing the oil in the vibrator head
Take the machine to your WACKER contact to change the oil in the vibrator
head.
Machine
type
Dimensions for vibrator head and lower tube
[mm]
øL
L
L
L
øL
L
IR... 30
28
(30)
347
(353)
— *
* Vibrator head does not comprise 2 parts.
— *
IR... 38
33
(38)
338
(345)
36
(38)
218
IR... 45
38
(45)
372
(382)
42
(45)
333
IR... 57
IR... 57k
50
(58)
390
(400)
320
(330)
54
(58)
54
(58)
253
213
IR... 65
52
(65)
475
(490)
58
(65)
322