Using DC Power
Overview
The DC terminals
(e)
are to be used only for charging 12V batteries. Maximum
available power is 12V–8.3A (100W).
Prerequisites
Verify that the engine is operating.
Verify that the voltage displayed on the LCD
(j)
is approximately 120V.
Verify that nothing is connected to the AC outlets.
Make sure that the charging cables to be used are rated for 12V and the
maximum CCA rating of the battery.
Engine switch
position
Leave the engine switch
(h)
in the RUN position while the generator is operating.
WARNING
Risk of machine damage and electric shock.
f
Do not use AC power and DC power at the same time.
WARNING
Personal injury hazard. Battery acid is corrosive to metallic surfaces and harmful to
human skin.
f
Wear protective clothing, goggles and gloves when working near batteries.
f
If battery acid contacts the skin or eyes, rinse immediately with clear water and
seek immediate medical attention.
WARNING
Explosion hazard. Explosive hydrogen gas is discharged through battery vent holes
during the charging process.
f
Do not use open flames or smoke near batteries.
f
Do not place metallic objects on or near the battery terminals. Metallic objects in
contact with both poles of the battery will generate extreme heat and potentially
ignite explosive battery gases.
wc_gr006668
h
e
e2
e1
f