GP/GPS 5600A
Operation
wc_tx000789gb.fm
33
3.14
Twist-Lock Receptacles
Twist-lock receptacles
(c, j)
are used at the 120V Amp and 120/240V
outlets. These receptacles are protected by the GFCI.
To attach a power cord to a twist-lock receptacle, insert plug into
receptacle and turn it clockwise to lock it in place.
3.15
Engine Auto Idle
The auto idle switch
(b)
automatically reduces engine speed
approximately 7 seconds after all appliances or tools attached to the
generator have been turned off. The engine automatically returns to
full speed when a tool or appliance is turned back on.
To turn the auto idle feature on, push the auto idle switch to “AUTO”.
The AUTO setting is recommended while the generator is running to
minimize fuel consumption. To avoid extended engine warm-up
periods, keep switch set to “OFF” when starting the engine and until
the engine reaches operating temperature.
3.16
Engine Speed
Generators require a fixed engine speed to maintain the correct
voltage. Engine speed is controlled by a governor which automatically
adjusts to varying loads on the engine to maintain a constant speed.
See
Technical Data
. There is no throttle control. Use the Auto Idle
switch on the generator to control engine speed.