Technical Data

GP 2600

wc_td000196gb.fm

34

5.

Technical Data

5.1

Generator

  

Item No.

GP 2600

0620088

Generator

Maximum Output

W

2600

Continuous Output

W

2250

Type

Single voltage, single phase,

Auto voltage regulator system

AC Voltages Available

volts

phase

120

1

Frequency

Hz

60

Power Factor

1.0

AC receptacles:
125V GFI duplex
125V duplex

amp
amp

20
20

Main Circuit Breaker

amp

20

L x W x H

mm (in.)

615 x 435 x 545

(24.2 x 17 x 21.5)

Weight (dry)

Kg (lbs.)

47.7 (105)

Summary of Contents for GP 2600

Page 1: ...Generator Non CARB GP 2600 OPERATOR S MANUAL 0170798en 001 0408 0 1 7 0 7 9 8 E N...

Page 2: ...enclosed areas Deadly levels of carbon monoxide can build up in these areas Using a fan or opening windows and doors does NOT supply enough fresh air ONLY use a generator outside and far away from wi...

Page 3: ...16 3 2 Installation 17 3 3 Generator Derating 18 3 4 Grounding the Generator 19 3 5 Operating Heavy Loads 19 3 6 Use of Extension Cords 20 3 7 Control Panel 21 3 8 Ground Fault Interrupt GFI 22 3 9 C...

Page 4: ...Table of Contents GP 2600 wc_bo0170798en_001TOC fm 4 5 Technical Data 34 5 1 Generator 34 5 2 Engine 35...

Page 5: ...ase contact Wacker Corporation The information contained in this manual was based on machines in production at the time of publication Wacker Corporation reserves the right to change any portion of th...

Page 6: ...n minor or moderate injury NOTICE Used without the safety alert symbol NOTICE indicates a hazardous situation which if not avoided could result in property damage Note Contains additional information...

Page 7: ...uirements may exist and improper connection may lead to equipment damage fire and personal injury or death Familiarity and proper training are required for the safe operation of the machine Machines o...

Page 8: ...position and operate the generator on a firm noncombustible level surface 2 2 14 ALWAYS transport the generator in an upright position 2 2 15 ALWAYS keep the machine far away from structures buildings...

Page 9: ...cannot see or smell 2 3 2 NEVER use a generator inside an enclosed area such as a tunnel or a trench 2 3 3 DO NOT smoke while operating the machine 2 3 4 DO NOT smoke when refueling the engine 2 3 5...

Page 10: ...ve the machine and allow the machine to dry before servicing 2 4 5 DO NOT service the machine if your clothing or skin is wet 2 4 6 DO NOT allow untrained personnel to service this equipment Only trai...

Page 11: ...GP 2600 Safety Information wc_si000196gb fm 11 2 5 Label Locations GND 88897...

Page 12: ...ation hazard Read the Operator s Manual for instructions DANGER Improper connection of generator to a building s electrical system can allow electrical current from the generator to backfeed into util...

Page 13: ...n wc_si000196gb fm 13 CAUTION Use only clean filtered gasoline fuel Check the fuel level Open the fuel flow valve Close the choke Turn the engine switch to the ON position Pull the rewind starter Open...

Page 14: ...LL YOU IN MINUTES Generator exhaust contains carbon monoxide This is a poison you cannot see or smell NEVER use inside a home or garage EVEN IF doors and windows are open Only use OUTSIDE and far away...

Page 15: ...nit Please record the information found on this plate so it will be available should the nameplate become lost or damaged When ordering parts or requesting service information you will always be asked...

Page 16: ...or dealer of the tool or appliance with questions regarding its power requirements NOTICE If a tool or appliance does not reach full speed within a few seconds when switched on turn it off immediately...

Page 17: ...e moisture Using a generator indoors CAN KILL YOU IN MINUTES Generator exhaust contains carbon monoxide This is a poison you cannot see or smell NEVER use this generator inside a home or garage EVEN I...

Page 18: ...e also affects the cooling capacity of air the higher the altitude the less dense the air is and thus the lower its ability to transfer heat For every increase in altitude of 500 m 1650 ft above 1000...

Page 19: ...source This ground connection must comply with National Electrical Code standards and state and local regulations 3 5 Operating Heavy Loads Limit operations requiring the maximum rated output of 2600...

Page 20: ...s Damaged extension cords can cause electrical shock resulting in serious injury or death DO NOT use worn bare or frayed cords Replace damaged cords immediately Use the chart below as a guide for sele...

Page 21: ...tion wc_tx000558gb fm 21 3 7 Control Panel Ref Description Ref Description a GFI duplex receptacle 120V d GFI test button b Circuit breaker 20 Amp e GFI reset button c Duplex receptacle 120V f Engine...

Page 22: ...t run generator until the problem can be corrected To restore power to receptacle push the RESET button in If the RESET button pops out during operation stop the generator and check it and equipment f...

Page 23: ...oil level in engine fuel level condition of air cleaner tightness of external fasteners condition of fuel lines Note The engine is equipped with an oil alert system If the oil level in the engine drop...

Page 24: ...ke to the open position b1 3 11 4 Turn the engine switch to ON c1 3 11 5 Pull the starter rope d Note If the oil level in the engine is low the red LED at the engine switch will light and the engine w...

Page 25: ...r first 20 hrs Every 50 hrs Every 100 hrs Every 300 hrs Check the fuel level Check the engine oil level Inspect the air filter Replace as needed Check external hardware Check condition of the fuel lin...

Page 26: ...ental protection place a plastic sheet and a container under the machine to collect any liquid that drains off Dispose of this liquid in accordance with environmental protection legislation 4 3 3 Inst...

Page 27: ...of low flash point solvents for cleaning the air cleaner A fire or explosion could result To service 4 4 1 Remove the air cleaner cover a Inspect the foam elements b for holes or tears Replace the ele...

Page 28: ...Do not touch the muffler while it is hot Note Refer to section Technical Data for the recommended spark plug type and the electrode gap setting 4 5 1 Remove the spark plug and inspect it 4 5 2 Replac...

Page 29: ...gine oil into the cylinder Crank the engine a few turns to distribute the oil to the inside of the cylinder walls 4 6 6 Pull the starter rope slowly until resistance is felt and leave the handle in th...

Page 30: ...is tight Engine oil level is adequate If engine starts but there is no power at receptacles check that Circuit breaker is closed Connector from generator to control panel is tight If engine starts bu...

Page 31: ...GP 2600 Maintenance wc_tx000559gb fm 31 Notes...

Page 32: ...et Cl Clear Sh Shield P Pink W White Gr Gray LL Light blue Ref Description Ref Description Ref Description A Generator B Control Box C Engine Ref Description Ref Description 1 Main stator winding 7 Du...

Page 33: ...GP 2600 Maintenance wc_tx000559gb fm 33 ORG ORG BLK BLK wc_gr004573...

Page 34: ...600 Continuous Output W 2250 Type Single voltage single phase Auto voltage regulator system AC Voltages Available volts phase 120 1 Frequency Hz 60 Power Factor 1 0 AC receptacles 125V GFI duplex 125V...

Page 35: ...Power kW Hp 4 2 5 7 Spark Plug NGK BR6HS Champion RL86C Electrode Gap mm in 0 6 0 7 0 024 0 028 Operating Speed Max rpm 3600 Air Cleaner type Dual Element Engine Lubrication oil grade SAE 10W30 SE or...

Page 36: ...02 0 Fax 49 0 89 3 54 02 3 90 Wacker Corporation P O Box 9007 Menomonee Falls WI 53052 9007 Tel 262 255 0500 Fax 262 255 0550 Tel 800 770 0957 Wacker Asia Pacific Operations Skyline Tower Suite 2303 2...