GP 2500A
Maintenance
wc_tx000448gb.fm
37
5.9
Long-Term Storage
Before storing the generator for a long period of time:
5.9.1
Close the fuel valve and remove and empty the sediment cup or fuel
strainer.
5.9.2
Disconnect the fuel line from the carburetor. Place the open end of the
fuel line into a suitable container and open the fuel valve to drain the
fuel from the tank.
Gasoline is extremely flammable. Drain the fuel tank in a well-
ventilated area. DO NOT drain the fuel tank in an area with flames or
sparks.
5.9.3
Loosen the drain screw on the carburetor and drain any remaining fuel
from the carburetor.
5.9.4
Change the engine oil.
5.9.5
Remove the spark plug and pour approximately 30 ml (1 ounce) of
clean engine oil into the cylinder. Crank the engine a few turns to
distribute the oil to the inside of the cylinder walls.
5.9.6
Pull the starter rope slowly until resistance is felt and leave the handle
in this position. This ensures that the intake and exhaust valves are
closed.
5.9.7
Store the generator in a clean, dry area.
5.10
Transporting the Machine
Let the engine cool before transporting the generator or storing it
indoors, to avoid burns or fire hazards.
When transporting the generator:
5.10.1 Turn the engine fuel valve to the OFF position.
5.10.2 Position the generator level to prevent fuel from spilling.
5.10.3 Secure the generator by tying it down with a suitable rope.
When transporting the machine by hand, be sure to employ manpower
commensurate with the weight of the machine. To avoid back injury
when lifting the machine, bend the knees to pick it up rather than
bending your back only.
WARNING
WARNING
WARNING
Summary of Contents for GP 2500A
Page 1: ...5200003184 01 0512 5 2 0 0 0 0 3 1 8 4 Operator s Manual Portable Generator GP 2500A EN...
Page 41: ...GP 2500A Technical Data wc_td000190gb fm 41 Notes...
Page 43: ...GP 2500A Schematics wc_tx001860gb fm 43 8 3 Electrical Schematic 8 11 9 10...
Page 44: ...Schematics GP 2500A 44 wc_tx001860gb fm...
Page 51: ......