Technical data
45
Example
You utilize an EH 23/115
and want to use an extension cable with a length of
36 m (118 ft).
The machine has an input voltage of 115 V.
According to the table, the extension cable must feature a cross-section area of
4 mm
2
(AWG 10).
230 1~
< 157
16
< 253
14
< 397
12
< 492
10
120 1~
< 95
14
< 148
12
< 236
10
127 1~
< 112
14
< 174
12
< 276
10
Voltage
[V]
Extension
[ft]
Cross-section
area of cable
[AWG]