T00806GB
15
MAINTENANCE
Maintenance schedule
Check all external screw connections for tight fit approx. 8 hours after first operation.
Parts
Maintenance jobs
Maintenance interval
Air filter
Check for external damage and tight fit.
daily
Check filter cartridge, clean or replace if necessary.
Fuel tank
Check tank lid for tight fit, replace if necessary.
Drive engine
Check oil level, top up if necessary.
Exciter
Check for tightness.
Drive engine
First oil change.
20 hours
Centre pole
Grease moveable locking device, and spindle or pole
monthly
height adjustment.
Drive engine
Clean spark plug, check spark plug gap 0,7 mm.
Centre pole head
Check oil level, top up if necessary.
V-belt
Check V-belt tension - retension, if need be
.
Protective frame
Check fastening screws of protective frame and
central suspension for tight fit.
Drive engine
Oil change.
100 hours
Exhaust muffler
Remove combustion residue from spark arrester.
Exciter
Oil change.
Exciter
Check oil level-fill up, if need be.
150 hours
Exciter
Oil change.
250 hours
Drive engine
Valve clearance - Check, set - 0,15 mm
300 hours
intake valve, 0,20 mm exhaust valve.