6-10
BA 901/1101 en – Edition 2.1 * 91101b610.fm
Technical data
6.13 Coolant compound table
6.14 Weights
Weight of options (selection)
Notice!
The actual machine weight depends on the selected options and must be read
off the type label.
Add the weight of all subsequently installed equipment to the weight of the
machine.
Weight indications can vary by +/
−
2 %.
Outside temperature
1
1.
Use the 1:1 concentration for warm outside temperatures, too, to ensure protection against corrosion, cavitation and deposits.
Water
Coolant
2
2.
Do not mix the coolant with other coolants.
Up to °C (°F)
% by volume % by volume
−
37 (
−
34.6)
50
50
Machine
Transport weight
1
kg (lbs)
1.
Transport weight = basic machine
Operating weight
2
kg (lbs)
2.
Operating weight = transport weight, full fuel tank, standard bucket 901 or 1101, operator (75 kg/165 lbs)
901
3406 (7,509)
3764 (8,298)
1101
4387 (9,672)
4752 (10,476)
Option
901
kg (lbs)
1101
kg (lbs)
Air conditioning
25 (55)
Sliding side window
31 (68)
Mudguard
40 (88)
High Flow
50 (110)
Cabin glazing
66 (146)
Rear weight
134 (295)
Summary of Contents for 901S
Page 10: ...I 8 BA 901 1101 en Edition 2 1 Ba91101en2_1SIX fm Index...
Page 34: ...1 24 BA 901 1101 en Edition 2 1 91101b110 fm Introduction...
Page 46: ...2 12 BA 901 1101 en Edition 2 1 91101b210 fm Safety instructions...
Page 50: ...3 4 BA 901 1101 en Edition 2 1 91101b320 fm Operation 3 3 Instrument panel overview...
Page 122: ...3 76 BA 901 1101 en Edition 2 1 91101b340 fm Operation...
Page 166: ...5 42 BA 901 1101 en Edition 2 1 91101b560 fm Maintenance Maintenance plan model 1101...