BA 901/1101 en – Edition 2.1 * 91101b510.fm
5-3
Maintenance
Notice!
Fill up the tank with the correct fuel type at the end of each working day. This
prevents condensation water from forming in the fuel tank over night. Do not fill the
tank completely but leave some space for the fuel to expand.
Stationary fuel pumps
General
Only refuel from stationary fuel pumps. Fuel from barrels or cans is usually dirty.
Even the smallest particles of dirt can cause
• Increased engine wear
• Malfunctions in the fuel system and
• Reduced effectiveness of the fuel filters
Refueling from barrels
If refueling from barrels cannot be avoided, note the following points (see fig. 87):
• Barrels must neither be rolled nor tilted before refueling
• Protect the suction pipe opening of the barrel pump with a fine-mesh screen
• Immerse it down to a max. 15 cm above the bottom of the barrel
• Only fill the tank using refueling aids (funnels or filler pipes) with integral microfilter
• Keep all refueling containers clean at all times
Diesel fuel specification
Use only high-grade fuels
Wrong
Right
Fig. 87: Refueling from a barrel
Grade
Cetane
number
Use
• No. 2-D according to DIN
51601
Min. 45
For normal outside temperatures
• No. 1-D according to DIN
51601
For outside temperatures below 4 °C or for
operation above 1500 m altitude
Summary of Contents for 901S
Page 10: ...I 8 BA 901 1101 en Edition 2 1 Ba91101en2_1SIX fm Index...
Page 34: ...1 24 BA 901 1101 en Edition 2 1 91101b110 fm Introduction...
Page 46: ...2 12 BA 901 1101 en Edition 2 1 91101b210 fm Safety instructions...
Page 50: ...3 4 BA 901 1101 en Edition 2 1 91101b320 fm Operation 3 3 Instrument panel overview...
Page 122: ...3 76 BA 901 1101 en Edition 2 1 91101b340 fm Operation...
Page 166: ...5 42 BA 901 1101 en Edition 2 1 91101b560 fm Maintenance Maintenance plan model 1101...