E.H. Wachs
Part No. 14-MAN-35, Rev. 0-0616
17
Note: Never connect or disconnect quick couplers when the
HPU is on. Never connect or disconnect quick couplers
when the circuit is under pressure. See the pressure gauge.
O
PERATING
I
NSTRUCTIONS
Before starting the power unit, perform the following
checks:
•
Make sure the reservoir is filled to the required level
with hydraulic oil.
•
Make sure the cabinet door is secured with the panel
lock fasteners.
•
Make sure the power cable is securely connected to the
electrical cabinet.
•
Make sure the handheld control pendant is connected.
1.
Turn the flow control knob to the OFF position (all the
way counter-clockwise).
Figure 3-6. Turn the main switch on the front of the
cabinet to the ON position.
2.
On the handheld pendant, turn the POWER knob
counter-clockwise until the POWER ON indicator
lights up.