INSTALLATION INSTRUCTION
InvisiLED® Electronic Remote Transformer
EN-OD24100-RB2-T
Fixture Wires
Black or
Smooth
Fixture Wires
White or
Ribbed
Fixture Wires
Bare wire
(Ground)
House Wires
Black
(Hot)
House Wires
White
(Neutral)
House Wires
Green or Bare Copper
(Ground)
Fig. 1
Fig. 2
FEATURES:
•
Electronic short circuit, overload, over temperature protection with auto-reset
•
Class 2, UL listed
•
Suitable for damp location – Locations protected from weather and not subject to saturation with water or other liquids but subject to
moderate degrees of moisture.
•
InvisiLED outdoor tape is wet location listed, however install EN-OD24100-RB2-T in protected damp location. If wet location power supply is
required, refer to EN-O24100-RB2-T.
PREPARATION:
•
Shut off the power at the circuit breaker.
•
Carefully unpack your new fixture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.
•
Transformer is to be installed away from heat sources and accessible for service.
INSTALLATION: (FIG.1)
1. Loosen two cover screws (B1) and remove the cover (C1).
2. Secure transformer box to suitable mounting surface using mounting screw (D1).
CONNECT THE WIRES: (FIG.2)
3. Remove appropriate power feed knockout in transformer box.
4. Bring building wires into knockout using cable connector.
5. Connect the electrical wires as shown in Fig. 2, making sure that all wire connectors (A1) are secured.
6. Secure the cover (C1) by tightening the two screws (B1).
7. To utilize Electronic Low Voltage (ELV) dimming, wire black (line hot) and white(line neutral) in accordance to dimmer specifications.
8. Connect the output female connector of the power supply with the male connector of the InvisiLED outdoor tape. (as Fig.3).
Cover Screw
Wire Conduit
(not included)
Wire Connector
Cover
B1
C1
A1
Mounting Screw
Female Waterproof
Connector
E1
Fig. 3
Power Supply
Tape Section
Securely tighten by hand
D1