![background image](http://html1.mh-extra.com/html/wac-lighting/ds-ws05/ds-ws05_installation-instructions_3115530003.webp)
WAC Lighting
www.waclighting.com
Phone (800) 526.2588 • Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive • Port Washington, NY 11050
Phone (516) 515.5000 • Fax (516) 515.5050
Western Distribution Center
1750 Archibald Ave • Ontario, CA 91761
Phone (800) 526.2588 • Fax (800) 526.2585
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. MArCh, 2015
REFLECTOR REPLACEMENT
1. Remove panel assembly by loosening the fixture screw and gasket, remove three chips to change reflector. (FIG.3)
2. Replace your beam angle reflector on panel and fix the clips. (FIG.4)
LED REPLACEMENT
1. Loosen the screw and gasket (See FIG.5), remove the panel assembly (See FIG.6).
2. Loosen the LED holder and LED screws, carefully disconnect LED connector from driver connector and replace LED by removing LED
mounting screws. (See FIG.7).
DRIVER REPLACEMENT
1. Loosen the screw and gasket (See FIG.8), remove the cover assembly (See FIG.9).
2. Loosen the LED driver screws, carefully disconnect LED driver connector from LED connector and replace driver by removing driver
mounting screws. (See FIG.10).
COMPLETING THE INSTALLATION
To prevent moisture from entering the outlet box and causing a short, use clear caulking (i.e. indoor/outdoor silicone sealant) to outline the
outside of fixture plate where it meets the wall leaving a space at bottom to allow moisture a means to escape.
Remove three clips
Replace different
beam angle reflector
Loosen the fixture
screws and gaskets
Loosen the fixture
screws and gaskets
Remove panel
assembly
Remove panel
assembly
LED holder
LED holder
Screws
Connector
LED
Put on reflector
and fix clips
FIG.3
FIG.5
FIG.8
FIG.6
FIG.9
FIG.7
FIG.10
FIG.4
INSTALLATION INSTRUCTION
Tube Architectural - LED Wall Mount
DS-WS05, WS06, WS08, DS-WD05, WD06, WD08