background image

 1 

[email protected]

HEIGHT:

8’2” or 2.49m

12 x 12 Arched Roof Pergola

with Plinth

Installation and Operating Instructions – YM11635

Yardistry – North America

Toll Free Customer Support: 1.888.509.4382

[email protected]

www.yardistrystructures.com

Yardistry / Selwood Products – Europe

Customer Support: +44 1284 852569

[email protected]

www.selwoodproducts.com

Revised 02/13/2013

10’

 (3.05 m)

12’

 (3.66 m)

3.05 m (10’)

3.66 m (12’)

Summary of Contents for YM11635

Page 1: ...g Instructions YM11635 Yardistry North America Toll Free Customer Support 1 888 509 4382 info yardistrystructures com www yardistrystructures com Yardistry Selwood Products Europe Customer Support 44 1284 852569 parts selwoodproducts com www selwoodproducts com Revised 02 13 2013 10 3 05 m 12 3 66 m 3 05 m 10 3 66 m 12 ...

Page 2: ...oo close to a Yardistry structure Consult user s manual of the grill fire pit or chimnea for safe distances from combustible materials Wear gloves to avoid injury from possible sharp edges of individual elements before assembly During installation follow all safety warnings provided with your tools and use OHSA approved safety glasses Some structures may require two or more people to install safel...

Page 3: ... not limited to wind storms hail floods excessive water exposure Minor twisting warping checking or any other natural occurring properties of wood that do not affect performance or integrity Yardistry products have been designed for safety and quality Any modifications made to the original product could damage the structural integrity of the product leading to failure and possible injury Yardistry...

Page 4: ...th of use and then annually Do not over tighten as to cause crushing and splintering of wood Check for sharp edges or protruding screw threads add washers if required WOOD PARTS Unprotected they will appear weathered over time Periodic application of an exterior water repellent or stain water based will help improve appearance and life Check all wood members for deterioration structural damage and...

Page 5: ... mounting to concrete footers see below for the correct locations and placement Please double check for possibility of any underground utilities such as gas telephone cable or sprinkler lines Following are some examples of how to mount the structure to wood or concrete surfaces Refer to your local building and city codes ordinances neighbourhood covenants or height restrictions regarding this type...

Page 6: ...ete Patio min 10 2 x 10 2 with 12 clearance on all sides Wood Deck min 10 2 x 10 2 with 12 clearance on all sides 10 x 1 1 4 Pan Screws Included 10 x 1 1 4 Pan Screws Included Anchoring Hardware not included Anchoring Hardware not included Room L Mount 10 x 1 1 4 Pan Screw Post ...

Page 7: ...orizontal Insert 185 Engineered Panel Corner Post 025 Engineered Panel Post 024 Cross Brace Insert 189 X Insert Trellis End 33 1 2 062 Beam End 34 1 4 192 Trellis End 110 1 2 061 Beam End 10 1 2 069 Bottom Brace Insert 191 Beam 20 3 4 067 L Mount Left Arch Gusset Left 194 Plinth Short A Assembly 027 Plinth Short B Assembly 028 2 x 3 Trellis Clip Plinth End Assembly 029 ...

Page 8: ...32pc 185 Horizontal Insert 2 x 2 x 16 1 8 Box 2 38 1 x 139 7 x 870 0mm 38 1 x 38 1 x 574 7mm 38 1 x 139 7 x 527 1mm 38 1 x 38 1 x 409 6mm 38 1 x 63 5 x 850 9mm 38 1 x 63 5 x 2806 7mm 38 1 x 76 2 x 409 6mm 36 x 69 9 x 2311 4mm 36 x 127 x 453 2mm 38 1 x 139 7 x 266 7mm 36 x 127 x 453 2mm Part Identification Dimensions are approximate and are shown to assist in the identification of parts for assembl...

Page 9: ...aller or larger 34 9 x 152 4 x 492 1mm 4pc 028 Plinth Short B Assembly Box 2 34 9 x 152 4 x 492 1mm 4pc 027 Plinth Short A Assemlby Box 2 34 9 x 152 4 x 598 5mm 8pc 026 Plinth Long Assembly Box 2 34 9 x 152 4 x 141 3mm 8pc 029 Plinth End Assembly Box 2 Corner Post 3 x 3 x 91 Box 2 4pc 190 69 9 x 69 9 x 2311 4mm Arch Beam Front 2 x 6 x120 Box 1 2pc 195 38 1 x 241 3 x 3048 0mm Arch Beam Offset 2 x 6...

Page 10: ...02 2pc 3 16 Hex Key Y00400 003 16pc 1 4 Connector Nut Y08420 205 9pc 1 4 Lock Nut Y08420 203 8pc Wafer Bolt 1 4 x 4 1 4 Y07420 241 9pc Wafer Bolt 1 4 x 2 Y07420 220 50pc Pan Screw 10 x 1 1 4 Y06420 911 83pc Wood Screw 10 x 4 Y06420 940 144pc Wood Screw 8 x 3 Y06420 530 48pc Wood Screw 8 x 2 1 2 Y06420 522 8pc L Mount Right Y00419 005 Hardware Identification Dimensions are approximate and are shown...

Page 11: ...ies or sprinkler line locations prior to excavating any holes D Before you discard your cartons fill out the form below The carton I D stamp is located on the end of each carton Please retain this information for future reference You will need this information if you contact the Consumer Relations Department Each step indicates which bolts and or screws you will need for assembly as well as any fl...

Page 12: ...8 1 x 574 7 mm 2 x 2 x 22 5 8 Hardware Wood Parts Fig 2 1 32 x X Insert Pin A Place one X Insert Pin into one X Insert then attach a second X Insert to form a complete Insert Make sure the pieces are tight to each other B Repeat Step A to make 32 complete Inserts X Insert Pin X Insert ...

Page 13: ...n in fig 3 1 C Set one Horizontal Insert between the posts and tight to Bottom Brace Insert Attach with two 8 x 3 Wood Screw as shown in figure 3 1 32 x 8 x 3 Wood Screw 024 Engineered Panel Post 8 x 024 Engineered Panel Post 36 x 69 9 x 2311 4 mm 2 x 4 x 91 8 x 191 Bottom Brace Insert 38 1 x 69 9 x 409 6 mm 2 x 4 x 16 1 8 8 x 185 Horizontal Insert 38 1 x 38 1 x 409 6 mm 2 x 2 x 16 1 8 8 x 025 Eng...

Page 14: ...a 189 Cross Brace Insert Attach all three Horizontal Inserts with two 8 x 3 Wood Screws per insert and attach Cross Brace Insert with four 8 x 3 Wood Screws fig 3 3 80 x 8 x 3 Wood Screw 024 Engineered Panel Post 32 x Completed Inserts from Step 2 8 x 189 Cross Brace Insert 38 1 x 76 2 x 409 6 mm 2 x 4 x 91 24 x 185 Horizontal Insert 38 1 x 38 1 x 409 6 mm 2 x 2 x 91 Fig 3 3 185 Horizontal Insert ...

Page 15: ... pre drill two holes from the inside at the places shown in fig 4 1 and 4 2 Pre drill in the centre of the panel and on a slight angle Fig 4 2 Note Only pre drill one post per assembly Fig 4 1 pre drill 3 holes from the centre on a slight angle Pre drill on a slight angle 024 Engineered Panel Post 025 Engineered Panel Corner Post ...

Page 16: ...11 4 mm 3 x 3 x 91 Fig 4 3 B Through the pre drilled holes attach two Panel Posts assemblies to one 190 Corner Post with one 10 x 4 Wood Screw per Panel Post Assembly at bottom and six 8 x 2 1 2 Wood Screws along post as shown in fig 4 3 Complete this step for all four Corner Posts 190 Corner Post 8 x 2 1 2 Wood Screws 8 x 2 1 2 Wood Screws 10 x 4 Wood Screws 8 x 2 1 2 Wood Screws Flush ...

Page 17: ...th two 10 x 1 1 4 Pan Screw per L Mount as shown in fig 5 1 5 2 and 5 3 Step 5 Attach L Mount Brackets Fig 5 1 Fig 5 2 Hardware 16 x Room L Mount Right and Left 32 x 10 x 1 1 4 Pan Screw 10 x 1 1 4 Pan Screw Flush to bottom of posts x 2 per L Mount L Mount Left L Mount Right L Mount Left L Mount Right Note orientation of tabs Fig 5 3 L Mount Right L Mount Left Note Flush to the inside edge ...

Page 18: ...ner Post Assembly Part 1 A Place one 028 Plinth Short B Assembly with one 027 Plinth Short A Assembly tight to each other and attach using two 6 x 30 mm Trim Screw at the opposite corners per Plinth Fig 6 1 and 6 2 Note Plinths will be attached to four corners Fig 6 1 Fig 6 2 16 x 6 x 30 mm Trim Screw 4 x 027 Plinth Short A Assembly 34 9 x 152 4 x 492 1 mm 4 x 028 Plinth Short B Assembly 34 9 x 15...

Page 19: ...tach Plinths to Corner Post Assembly Part 2 B On the outside of the corner post assembly place two 026 Plinth Long Assembly tight against eachother using 2 6 x 30 mm Trim Screws per Plinth Be sure they are flush and tight Fig 6 3 and 6 4 Fig 6 3 Fig 6 4 16 x 6 x 30 mm Trim Screw 8 x 026 Plinth Long Assembly 34 9 x 152 4 x 598 5 mm ...

Page 20: ... Plinth End Assembly Step 6 Attach Plinths to Corner Post Assembly Part 3 C Place one 029 Plinth End Assembly onto each Corner Post Assembly Line them up with previously placed Plinths Make sure they are flush and tight to each other and then fasten with two 6 x 30 mm Trim Screw per end Fig 6 5 and 6 6 Fig 6 5 Fig 6 6 16 x 6 x 30 mm Trim Screw 8 x 029 Plinth End Assembly 34 9 x 152 4 x 141 3 mm ...

Page 21: ... lined up flush and level before installing remaining screws D After the Plinth Ends have been placed go back and install the two remaining 6 x 30 mm Trim Screws per end to the assembled Plinth of the Pergola Room Fig 6 7 and 6 8 E Attach 2 6 x 30 mm Trim Screws to each end side as shown in fig 6 7 and 6 8 Fig 6 7 Fig 6 8 48 x 6 x 30 mm Trim Screw ...

Page 22: ...quare as shown in fig 7 1 The distance from the outside of one Corner Post to the outside of a second Corner Post should be 120 See fig 7 1 and 7 2 for accurate placement and additional measurements 1 6 9 1 1 1 6 120 X4 78 5 X4 78 5 120 120 78 5 169 11 16 move to final position Fig 7 2 78 1 2 78 1 2 78 1 2 C Depending on what you are placing the Pergola Room on will determine how you anchor it to ...

Page 23: ...ace attach one 069 Beam End 10 1 2 to 192 Beam End 34 1 4 with three 10 x 4 Wood Screws as shown in fig 8 1 B Repeat Step A three more times so you have four assemblies Note that two of the Beam Ends should be on the same side as the cut out and two should be on the opposite side fig 8 1 and 8 2 069 Beam End 10 1 2 192 Beam End 34 1 4 Fig 8 2 10 x 4 Wood Screws 10 x 4 Wood Screws 069 Beam End 10 1...

Page 24: ...afer Bolt 5 16 flat washer 1 4 connector nut 4 x 1 4 x 3 3 4 Wafer Bolt 5 16 flat washer 1 4 connector nut 068 Beam 81 1 2 Beam End Assembly Fig 9 1 8 x 3 Wood Screw Cut out Flat Washer 1 4 x 4 1 4 Wafer Bolt Flat Washer Beam End Assembly Beam End Assembly 068 Beam 81 1 2 Panel Post B Fit one 068 Beam 81 1 2 in between two Corner Post Assemblies and attach to Beam End assemblies and Panel Post as ...

Page 25: ...1 4 connector nut per side fig 10 1 B Attach three 8 x 3 wood screws per side C Repeat for the opposite side Step 10 Attach Arch Beam Fronts 2 x 195 Arch Beam Front 38 1 x 241 3 x 3048 mm 2 x 6 x 120 Hardware Wood Parts Fig 10 2 12 x 8 x 3 Wood Screw 4 x 1 4 x 4 1 4 Wafer Bolt 5 16 flat washer 1 4 connector nut 4 x 1 4 x 3 3 4 Wafer Bolt 5 16 flat washer 1 4 connector nut Fig 10 1 1 4 x 4 1 4 Wafe...

Page 26: ...h one 8 x 2 1 2 Wood Screw and six 10 x 4 Wood Screws per Beam 20 3 4 as shown in fig 11 1 and 11 2 Step 11 Attach Arch Beam Offsets 2 x 080 Arch Beam Offset 38 1 x 241 3 x 3048 mm 2 x 6 x 120 4 x 067 Beam 20 3 4 38 1 x 139 7 x 527 1 mm 2 x 6 x 20 3 4 Hardware Wood Parts Fig 11 2 36 x 10 x 4 Wood Screw 8 x 8 x 2 1 2 Wood Screw 080 Arch Beam Offset Fig 11 1 8 x 2 1 2 Wood Screw Engineered Panel Pos...

Page 27: ...2 C Repeat Steps A and B until there are 9 Trellis End Assemblies Step 12 Assemble Trellis Ends 9 x 062 Trellis End 33 1 2 38 1 x 63 5 x 850 9 mm 2 x 3 x 33 1 2 9 x 061 Trellis End 110 1 2 38 1 x 63 5 x 850 9 mm 2 x 3 x 110 1 2 Hardware Wood Parts Fig 12 2 9 x Trellis Clip 9 x 1 4 x 2 Wafer Bolt 1 4 lock nut 062 Trellis End 33 1 2 Fig 12 1 1 4 x 2 Wafer Bolt 1 4 Lock Nut 061 Trellis End 110 1 2 06...

Page 28: ...ed in fig 13 1 and 13 2 C Attach Trellis Clip to Arch Beam Offset with two 10 x 1 1 4 Pan Screws as shown in fig 13 1 and 13 3 Step 13 Attach Trellis End Assemblies Part 1 Hardware 3 x 10 x 4 Wood Screw 2 x 10 x 1 1 4 Pan Screw 10 x 4 Wood Screw 10 x 1 1 4 Pan Screw 59 1 4 59 1 4 Beam 81 1 2 Trellis End Assembly Arch Beam Offset Arch Beam Front Arch Beam Offset Arch Beam Front Trellis Clip Fig 13 ...

Page 29: ... on opposing sides to the assemblies next to it fig 13 5 Note The distance between assemblies should be 12 fig 13 6 Note Refer to previous page fig 13 2 and 13 3 for attaching trellis clip Step 13 Attach Trellis End Assemblies Part 2 Hardware 24 x 10 x 4 Wood Screw 16 x 10 x 1 1 4 Pan Screw Fig 13 6 Fig 13 5 Start here and move outwards on either side alternating trellis assemblies so Trellis Clip...

Page 30: ...posing corners Attach a 194 Arch Gusset Left on the other two corners B Repeat for opposite side Step 14 Attach Left and Right Arch Gussets Part 1 193 Arch Gusset Right Fig 14 1 194 Arch Gusset Left 2 x 193 Arch Gusset Right 36 x 127 x 453 2 mm 2 x 5 x 17 27 32 2 x 194 Arch Gusset Left 36 x 127 x 453 2 mm 2 x 5 x 17 27 32 Hardware Wood Parts 8 x 8 x 2 1 2 Wood Screw 4 x 8 x 3 Wood Screw Fig 14 2 8...

Page 31: ...o the 080 Arch Beam Offset with two 8 x 2 1 2 Wood Screws as shown in fig 14 3 and 14 4 Each corner of the assembly should have one Arch Gusset Right and one Arch Gusset Left 193 Arch Gusset Right Fig 14 3 Hardware Wood Parts Fig 14 4 Panel Post Beam 20 3 4 Step 14 Attach Left and Right Arch Gussets Part 2 2 x 193 Arch Gusset Right 36 x 127 x 453 2 mm 2 x 5 x 17 27 32 2 x 194 Arch Gusset Left 36 x...

Page 32: ...32 support yardistrystructures com NOTES ...

Page 33: ...33 support yardistrystructures com NOTES ...

Page 34: ...this product for ease of assembly Excellent Very Good Average Below Average Poor How would you rate our instructions Excellent Very Good Average Below Average Poor How would you rate the quality of packaging Excellent Very Good Average Below Average Poor Would you recommend the purchase of our products to friends and family Yes No Comments MM DD YY REVISION 10 18 11 MAIL TO Yardistry c o Solowave ...

Reviews: