Step 3: Installing the Fixture 

8.  Screw the fixture onto the stake provided, leading the wire from 

the fixture through the wire slot in the stake. 

9.  If desired, bury your wire by digging a small trench. Close the 

trench by applying an inward force to both sides of the trench. 
 

Note:  For model 5012, wires MUST be buried at least 18” 
below the ground per NEC.

 

10.  Repeat steps for other fixtures in the same electrical circuit. 

11.  Turn the main power supply back on and make sure the fixtures 

light up. 
 
 
 
 
 
 

Step 4: Aiming the Fixture

 

12.  Tilting: Loosen the joint screw and adjust the head of the fixture 

to the desired direction before retightening the screw. 

13.  Rotating: Loosen the mounting knob and rotate the fixture to 

the desired position before retightening the knob. 
 
 
 
 
 
 
 
 

Step 5: Dimming Adjustment:

14.  Use a Phillips head screwdriver to adjust the dimming dial. 

15.  Rotate until the arrow on the dial is pointed at the desired 

wattage. The wattage may be adjusted to the pre-existing tabs 
or any value in between. 

16.  The lower the wattage, the dimmer the fixture will be.  

17.  Please refer to the yellow tag to determine the size of the 

required transformer.

4W

*6.5W

2W

*3.5W

8W

*10.5W

13W

*13.5W

16W

*14.5W

Model: 5011

Model: 5012 

*Numbers not printed  

on fixture

Joint Screw

Mounting 
Knob

Tilting

Rotating

Runs to 
the next 
fixture

Transformer