Wabtec NIEAF SMITT NI 98III Manual Download Page 27

27

www.nieaf-smitt.nl

                      Nieaf-Smitt is a brand name of Mors Smitt 

8  

Accessoires

De volgende accessoires worden standaard meegeleverd:

Holster incl. steun

• 

Batterij (9 V, reeds geplaatst)

• 

Handleiding

• 

Meetsnoeren

• 

Temperatuur meetsensor (alleen NI 99III)

• 

Ophangmagneet

• 

Summary of Contents for NIEAF SMITT NI 98III

Page 1: ...Nieaf Smitt is a brand name of Mors Smitt NI 98III NI 99III Handleiding Manual ...

Page 2: ...ny form or manner either electronically mechanically by photo copying recording or in any manner without prior written consent from Mors Smitt B V This also applies to accompanying drawings and diagrams Due to a policy of continuous development Mors Smitt B V reserves the right to alter the equipment specification and description outlined in this datasheet without prior notice and no part of this ...

Page 3: ...en 12 5 Werking Spanningmeting 13 Stroommeting 14 Frequentie 15 Weerstand capaciteitmeting 16 Continuiteit diodemeting 17 Temperatuur alleen NI 99III 18 6 Specificaties Algemene specificaties 19 Omgevingsomstandigheden 19 Electrische specificaties 20 1 Spanning 20 2 Auto V LOZ 21 3 Stroom 21 4 Peak hold 22 5 Weerstand 22 6 Doorgangstest 22 7 Diode test 22 8 Capaciteit 23 9 Frequentie 23 10 Tempera...

Page 4: ... meldingen duiden op omstandigheden of handelingen die tot ongevallen zouden kunnen leiden Symbolen op het product Zie de handleiding Dubbel geïsoleerd DC meting AC meting Batterij indicator Zekering Hoogspanning Geeft de conformiteit met de Europese richtlijnen aan Voer dit product alleen af volgens de lokale regelingen Specifieke voorzorgsmaatregelen Niet gebruiken met open behuizing Zet om verw...

Page 5: ...oorslag spanning van de zekering van de multimeter Controleer vooraf met de spanningsfunctie de spanningen in het te meten circuit Vervang defecte zekeringen met zekeringen van dezelfde waarden zoals aangegeven in de handleiding Wees voorzichtig bij spanningen boven 30 VAC RMS 42 VAC peak en 60 VDC Deze spanningen hebben gevaar voor schokken Vervang de batterij zodra het low battery symbool in het...

Page 6: ...itale display Weergave met analoog staafdiagram bestaand uit 62 segmenten Extra grote display met in uit schakelbare heldere verlichting True RMS 0 08 basis VDC nauwkeurigheid Automatische AC DC spanning detectie met lage impedantie Auto V LoZ VoltSense contactloze spannings detectie Smart data hold Peak hold 1 ms alleen NI 99III Min max functie AC DC functie Frequentie Capaciteit meting Temperatu...

Page 7: ...el van de meter Display 1 Functietoetsen 2 Draaischakelaar 3 A ingangsklem 4 V Ω ingang 5 COM ingang 6 mA ingang 7 Uitpakken en inspectie Nadat u uw nieuwe digitale multimeter uit de verpakking heeft gehaald moet u over de volgende artikelen beschik ken 1 Digitale multimeter 2 Set meetsnoeren één zwart één rood 3 Bedieningshandleiding 4 Beschermende houder 5 Ophangmagneet 6 K type temperatuur sens...

Page 8: ...ame of Mors Smitt 4 Functietoetsen Gele functie toets Druk op de gele functietoets om te schakelen tussen de verschillende beschikbare meetfuncties Range functie toets Functie Positie schakelaar Druk Druk toets om het display bereik te selecteren ...

Page 9: ...ort de minimale maximale gemeten waarde Middels de Min max toets kan de minimale en maximale gemeten waarde weergegeven worden Door de Min max toets 1 sec ingedrukt te houden wordt deze functie afgesloten Druk toets ca 1 seconde in om deze functie te verlaten Huidige meetwaarden Max meetwaarden Min meetwaarden ...

Page 10: ...gen Druk op de Hold toets om de meting te pauzeren Smart hold functie toets De Smart HOLD functie registreert of de gemeten meet waarde de waarde overschrijft die op de display word afgebeeld Indien deze waarde word overschreven klinkt een constante pieptoon Indien de gemeten waarde lager is dan 50 digit knippert de display Druk toets ca 1 seconde in om deze functie te verlaten Druk Huidige meetwa...

Page 11: ...ten elektrisch veld Tevens geeft de meter een acoustisch signaal welke naarmate de afstand tussen de gedetecteerde spanning en de bron kleiner wordt sneller klinkt Let op Indien er geen indicatie wordt gegeven is het mogelijk dat er nog steeds spanning aanwezig is Controleer de afwezigheid van spanning altijd met een 2 polige spanningstest Verlichting Middels de rode licht toets kan de display ver...

Page 12: ...k op een knop of draai de draaischakelaar om de meter weer te activeren Automatische uitschakeling uitschakelen De automatische uitschakeltijd kan worden uitgeschakeld door de gele knop op de meter ingedrukt te houden en de meter aan te zetten door middel van de draai schakelaar De melding Roff verschijnt op het display Slaapstand na 20 minuten ...

Page 13: ...n op de V Ω klem en 1 het zwarte meetsnoer op de COM klem Zet de draaischakelaar op V V of mV 2 Door middel van de gele toets is het mogelijk om de 3 functie van de meter aan te passen de mogelijkheden worden weer gegeven in het geel boven de stand waar de meter op staat Plaats de meetsnoeren op het te meten object 4 ...

Page 14: ...op de COM klem of gebruik de A en de COM klem in het 10 A bereik Zet de draaischakelaar op mA of A 2 Standaard staat de meter ingesteld op het meten van AC 3 met de gele toets kan er gekozen voor een DC of AC DC meting Op het display van de multimeter wordt er aangeduid in welke stand de meter staat Plaats de meetsnoeren op het te meten object 4 ...

Page 15: ...s Smitt Frequentie Sluit het rode meetsnoer aan op de V Ω klem en 1 het zwarte meetsnoer op de COM klem Zet de draaischakelaar op de V Hz stand 2 Druk eenmaal op de gele toets om de meter in Hz 3 stand te zetten Plaats de meetsnoeren op het te meten object 4 ...

Page 16: ...uit het rode meetsnoer aan op de V Ω klem 1 en het zwarte meetsnoer op de COM klem Zet de draaischakelaar op de Ω stand 2 Met de gele toets kan de functie van de meter worden 3 aangepast van Ω naar en terug Plaats de meetsnoeren op het te meten object 4 Weerstand Weerstand Capaciteit Capaciteit ...

Page 17: ...it het rode meetsnoer aan op de V Ω klem 1 en het zwarte meetsnoer op de COM klem Zet de draaischakelaar op de stand 2 Met de gele toets kan de functie van de meter worden 3 aangepast van een continuïteit meting naar een diode meting en weer terug Plaats de meetsnoeren op het te meten object 4 ...

Page 18: ...ratuur o C o F meting alleen NI 99III Sluit de van de sensor adapter aan op de V Ω klem 1 en de andere op de COM klem Zet de draaischakelaar op de stand 2 Met de gele toets kan de functie van de meter worden 3 aangepast van een o C naar een o F meting en weer terug Druk ...

Page 19: ...peratuur 10 o C 10 o C 10 o C 30 o C vochtigheidsgraad tot 80 30 o C 40 o C vochtigheidsgraad tot 75 40 o C 50 o C vochtigheidsgraad tot 45 Opslagtemperatuur 20 o C 60 o C vochtigheidsgraad 0 tot 80 als de batterij uit de meter wordt verwijderd Termperatuur coefficient 0 15 x gespecificeerde nauwkeurigheid o C 18 o C of 28 o C Gewicht 460 g incl batterijen Afmetingen lxhxd 94 x 190 x 48 mm incl ho...

Page 20: ... 1 V 0 09 2 d 0 08 2 d 60 0 m VAC 0 1 mV 1 20 5 d 600 0 m VAC 0 1 mV 1 5 5 d 1 20 5 d 6 000 VAC 0 001 V 1 0 3 d 0 80 5 d 60 00 VAC 0 01 V 1 0 3 d 0 80 5 d 600 0 VAC 0 1 V 1 0 3 d 0 80 5 d 1000 VAC 1 V 1 0 3 d 0 80 5 d Bescherming tegen overbelasting 1000 VAC DC RMS AC frequency 50 Hz 1 KHz Ingangsimpedantie 10 MW 100 pF Wisselstroom omvormingstype Wisselstroomomvormingen zijn gekop peld aan de wis...

Page 21: ...usgolf Bereik Resolutie Nauwkeurigheid NI 98III Nauwkeurigheid NI 99III 60 00 m ADC 0 01 mA 0 1 3 d 0 8 3 d 600 0 m ADC 0 1 mA 0 1 3 d 0 8 3 d 6 000 ADC 0 001 A 0 1 3 d 0 8 3 d 10 00 VDC 0 01 A 0 1 3 d 0 8 3 d 60 00 m AAC 0 01 mA 1 5 3 d 1 2 3 d 600 0 mAAC 0 1 mA 1 5 3 d 1 2 3 d 6 000 AAC 0 001 A 1 5 3 d 1 2 3 d 10 00 AAC 0 01 A 1 5 3 d 1 2 3 d Zekering Voorzien van hoogspanningszekering 440 mA 10...

Page 22: ...erming tegen overbelasting 1000 VAC DC RMS Open klemspanning Ca 2 5 V voor 600 W 6 k W bereik Max teststroom Ca 0 1 mA Bereik Resolutie Nauwkeurigheid 600 0 W 0 1 W 0 8 5 d Bescherming tegen overbelasting 1000 VAC DC RMS Open klemspanning Ca 2 5 V Max teststroom Ca 0 1 mA Drempel van geleidend vermogen 30 W beep aan 100 W beep uit Indicator van geleidend vermogen 2 7 KHz geluidsignaal Bereik Resol...

Page 23: ... 2 d 10 00 µF 0 01 µF 100 0 µF 0 1 µF 1 000 mF 0 001 mF 10 00 mF 0 01 mF Bescherming tegen overbelasting 1000 VAC DC RMS Max meettijd 0 7 sec voor 1 nF 1mF 3 sec voor 1 mF 10 mF Bereik Resolutie Nauwkeurigheid 100 00 Hz 0 01 Hz 0 1 2 d 1000 0 Hz 0 1 Hz 10 000 KHz 0 001 KHz 100 00 KHz 0 01 KHz Bescherming tegen overbelasting 1000 VAC DC RMS Min frequency 1 Hz Gevoeligheid 5 0 VDC voor ACV 1 Hz 10 k...

Page 24: ...ik Resolutie Nauwkeurigheid NI 98III Nauwkeurigheid NI 99III 60 00 mV 0 01 mV 2 0 10 d 600 0 mV 0 1 mV 2 5 5 d Aanvullende specificaties zijn identiek aan de spanningfunctie Bereik Resolutie Nauwkeurigheid NI 98III Nauwkeurigheid NI 99III 60 00 mA 0 01 mA 2 5 5 d 2 0 5 d 600 0 mA 0 1 mA Aanvullende specificaties zijn identiek aan de stroomfunctie Bereik Resolutie Nauwkeurigheid NI 98III Nauwkeurig...

Page 25: ...75 isopropylalcohol gebruiken om de meter nog beter schoon te maken Om schade aan het oppervlak van de meter te voorkomen dient u geen schuurmiddelen of chemische schoonmaakmiddelen te gebruiken Batterij vervangen Als het batterij symbool knipperend verschijnt moet de batterij vervangen te worden Haal de meetsnoeren los van de stroomkring die 1 gemeten wordt en schakel de meter uit Verwijder de me...

Page 26: ... de kast van de behuizing 4 Vervang de zekering door een nieuwe zekering 1 5 of zekering 2 Monteer de onderkant van de behuizing 6 Plaats de batterij die u eerder hebt verwijderd 7 en sluit de batterijdeksel Zekering 440 mA 1000 V 626006040 Zekering 11 A 1000 V 626006041 Waarschuwing het aanbrengen van onjuiste zekeringen kan tot ongevallen en schade aan het instrument leiden Batterij deksel Achte...

Page 27: ... Smitt is a brand name of Mors Smitt 8 Accessoires De volgende accessoires worden standaard meegeleverd Holster incl steun Batterij 9 V reeds geplaatst Handleiding Meetsnoeren Temperatuur meetsensor alleen NI 99III Ophangmagneet ...

Page 28: ...asurement 38 Current measurement 39 Frequency 40 Resistance capacitance 41 Continuity diode 42 Temperature NI 99III only 43 6 Specifications General specifications 44 Environmental specifications 44 Electrical specifications 1 Voltage 45 2 Auto V LOZ 46 3 Current 46 4 Peak hold 47 5 Resistance 47 6 Continuity check 47 7 Diode test 47 8 Capacitance 48 9 Frequency 48 10 Temperature NI 99III only 48 ...

Page 29: ...ify conditions or actions that could lead to accidents Symbols on the product See instruction manual Equipment protected by double or reinforced insulation DC measurement AC measurement Battery indicator Fuse Risk of electric shock Conforms to EU directives Do not discard this product or throw away Specific precautions Do not use with open housing To prevent injury never use the instrument to meas...

Page 30: ...not apply more than the rated voltage as marked on the meter between terminals or between any terminal and earth ground Only replace the blown fuse with the proper rating as specified in this manual Use caution with voltages above 30 VAC RMS 42 VAC peak or 60 VDC These voltages pose a shock hazard To avoid false readings that can lead to electric shock and injury replace battery as soon as low bat...

Page 31: ...splay with analog bar graph consisting of 62 segments Extra large display with on off switchable bright lighting True RMS 0 08 basic VDC accuracy Automatic AC DC voltage detection with low impedance Auto V LoZ VolteSense non contact voltage detection Smart data hold Peak hold 1 ms NI 99III only Min max function AC DC function Frequency counter in AC mode Capacity measurement Temperature NI 99III o...

Page 32: ...uttons 2 Rotary switch 3 Input terminal for A 4 Input terminal for V Ω C functions 5 Common ground reference input terminal 6 Input terminal for mA 7 Inspection Once your new digital multimeter has been unpacked from the original packaging you should have the following items Digital multimeter 1 Set of test leads one black one red 2 Operation manual 3 Protective holster 4 Hanging kit 5 K type temp...

Page 33: ...33 www nieaf smitt nl Nieaf Smitt is a brand name of Mors Smitt 4 Function buttons Yellow button Press the yellow function key to toggle between the various available measurement functions Range button ...

Page 34: ... The Min max mode records the min and max input values When the input goes below the recorded min value or above the recorded max value the meter records the new value Press the hold button to pause the recording By holding the Min max button for 1 sec this function will be ended ...

Page 35: ...lue when the inputs goes below the recorded peak minimum value or above the recorded peak maximum value the meter records the new value Press Hold button to pause the recording Smart hold The meter will beep continuously and the display will flash if the measured signal is larger than the display reading by 50 counts However it cannot detect across the AC and DC Voltage Current ...

Page 36: ...ection Hold the VoltSense button to use this function The number of dashes on the display indicated the strength of the electric field that is detected Warning If there is no indication voltage could still be present Illumination Through the red light button the backlight can be switched on or off ...

Page 37: ... 20 minutes of idle the multimeter will go into sleep mode Wake up the meter by dialing the switch or pressing any button Disable auto power off The auto power off function can be disabled by holding the yellow button and turning the multimeter on On the display Roff will be mentioned ...

Page 38: ...ct the red test lead to the V Ω connection 1 and the black test lead to the COM terminal Turn the rotation switch on V V or mV 2 By pressing the yellow button it is possible to change the 3 function that is indicated in yellow above the selected function Connect the test lead to the to measure object 4 ...

Page 39: ...the requested measuring that you want to make Connect the black test lead to the COM terminal Turn the rotation switch on mA or A 2 The meter is standard in AC mode by pressing the yellow 3 button it is possible to change the mode to DC or AC DC mode The display indicates what kind of mode is selected Connect the test lead to the to measure object 4 ...

Page 40: ...s Smitt Frequency Connect the red test lead to the V Ω terminal and 1 the black test lead to the COM terminal Set the rotary switch to the V Hz position 2 Press the yellow button to turn the meter in Hz mode 3 Connect the test lead to the to measure object 4 ...

Page 41: ...citance measurement Connect the red test lead to the V Ω terminal and 1 the black test lead to the COM Set the rotary switch to the V Ω position 2 By pressing the yellow button the measuring function can 3 be changed from Ω to mode Connect the test lead to the to measure object 4 ...

Page 42: ...nnect the red test lead to the V Ω terminal and 1 the black test lead to the COM terminal Set the rotary switch to the position 2 By pressing the yellow button the measuring function 3 can be changed from a Continuity measuring to a diode measuring Connect the test lead to the to measure object 4 ...

Page 43: ...t Temperature C F NI 99III only Connect the of the sensor to the V Ω terminal and 1 the other to the COM terminal Turn the switch on the temperature measuring mode 2 By pressing the yellow button the measuring value can be 3 changed from Celsius C to Fahrenheit F ...

Page 44: ... no backlight Auto Power Off 20 minutes Operating temperature 10 o C 10 o C 10 o C 30 o C 80 RH 30 o C 40 o C 75 RH 40 o C 50 o C 45 RH Storage temperature 20 o C 60 o C 0 to 80 RH batteries not fitted Temperature coefficient 0 15 x spec accy C 18 C or 28 C Dimensions 460 g incl batteries Dimensions lxhxd 94 x 190 x 48 mm incl holster Accessories Holster battery installed test leads hanging kit te...

Page 45: ...2 d 600 0 VDC 0 1 V 0 09 2 d 0 08 2 d 1000 VDC 1 V 0 09 2 d 0 08 2 d 60 0 m VAC 0 1 mV 1 20 5 d 600 0 m VAC 0 1 mV 1 5 5 d 1 20 5 d 6 000 VAC 0 001 V 1 0 3 d 0 80 5 d 60 00 VAC 0 01 V 1 0 3 d 0 80 5 d 600 0 VAC 0 1 V 1 0 3 d 0 80 5 d 1000 VAC 1 V 1 0 3 d 0 80 5 d Overload protection 1000 VAC DC RMS AC frequency 50 Hz 1 KHz Input impedance 10 MW 100 pF AC conversion type AC conversions are ac coupl...

Page 46: ...cy NI 98III Accuracy NI 99III 60 00 m ADC 0 01 mA 0 1 3 d 0 8 3 d 600 0 m ADC 0 1 mA 0 1 3 d 0 8 3 d 6 000 ADC 0 001 A 0 1 3 d 0 8 3 d 10 00 VDC 0 01 A 0 1 3 d 0 8 3 d 60 00 m AAC 0 01 mA 1 5 3 d 1 2 3 d 600 0 mAAC 0 1 mA 1 5 3 d 1 2 3 d 6 000 AAC 0 001 A 1 5 3 d 1 2 3 d 10 00 AAC 0 01 A 1 5 3 d 1 2 3 d Input protection Equipped with high energy fuse 440 mA 1000 VAC DC 10 KA fuse for mA input 11 A...

Page 47: ... 10 MW Input protection 1000 VAC DC RMS Max open circuit voltage Approx 2 5 V for 600 Ω 6 kΩ range Approx 0 6 V for others Max test current Ca 0 1 mA Range Resolution Accuracy 600 0 W 0 1 W 0 8 5 d Input protection 1000 VAC DC RMS Max open circuit voltage Ca 2 5 V Max test current Ca 0 1 mA Continuity threshold 30 W beep on 100 W beep off Continuity indicator 2 7 KHz tone buzzer Range Resolution A...

Page 48: ...µF 1 2 2 d 10 00 µF 0 01 µF 100 0 µF 0 1 µF 1 000 mF 0 001 mF 10 00 mF 0 01 mF Input protection 1000 VAC DC RMS Max measuring time 0 7 sec for 1 nF 1mF 3 sec for 1 mF 10 mF Range Resolution Accuracy 100 00 Hz 0 01 Hz 0 1 2 d 1000 0 Hz 0 1 Hz 10 000 KHz 0 001 KHz 100 00 KHz 0 01 KHz Input protection 1000 VAC DC RMS Min frequency 1 Hz Sensitivity 5 0 VDC for ACV 1 Hz 10 kHz 10 Vp p for ACV 10 kHz 10...

Page 49: ...V 1 V Additional specification are same as voltage function Range Resolution Accuracy NI 98III Accuracy NI 99III 60 00 mV 0 01 mV 2 0 10 d 600 0 mV 0 1 mV 2 5 5 d Additional specification are same as voltage function Range Resolution Accuracy NI 98III Accuracy NI 99III 60 00 mA 0 01 mA 2 5 5 d 2 0 5 d 600 0 mA 0 1 mA Additional specification are same as current function Range Resolution Accuracy N...

Page 50: ...owel A 75 isopropyl alcohol may be used in order to clean the meter properly To prevent damage to the surface of the meter do not use abrasives or chemical cleaners to clean the surface Battery replacement When the battery symbol starts flashing the battery should be replaced Remove the test leads from the circuit being 1 measured and turn off the meter Remove test leads from the meter 2 Loosen th...

Page 51: ...ry terminal and the bottom 4 housing of the meter from each other Remove the 4 screws from the PCB and the top of 5 the housing Replace the fuse with a new fuse 1 or fuse 2 6 Replace the bottom of the housing 7 Insert the battery that you previously removed and 8 replace the battery cover and tighten the screw Fuse 440 mA 1000 V 626006040 Fuse 11 A 1000 V 626006041 Warning the application of incor...

Page 52: ...ieaf Smitt is a brand name of Mors Smitt 8 Accessories The following accessories are included Holster including support Battery 9 V already installed Manual Test leads Temperature measurement sensor NI 99III only Hanging kit ...

Page 53: ...53 www nieaf smitt nl Nieaf Smitt is a brand name of Mors Smitt ...

Page 54: ...g from this edition may be multiplied or made public in any form or manner either electronically mechanically by photocopying recording or in any manner without prior written consent from Mors Smitt B V This also applies to accompanying drawings and diagrams Due to a policy of continuous development Mors Smitt B V reserves the right to alter the equipment specification and description outlined in ...

Reviews: