![WABCO TP0735 Installation Instructions Manual Download Page 25](http://html1.mh-extra.com/html/wabco/tp0735/tp0735_installation-instructions-manual_3110946025.webp)
25
Appendix II
7.1.5
Cable-to-Cable Connections
It is important to ensure all cable-to-cable connections maintain good strain relief. Cable restraints must
be placed between 2- and 4-inches (51-102 mm) from the cable connector to ensure correct strain relief.
Regardless of whether zip ties or cable clips are used, cables should be secured at intervals not greater
than 18-inches (457 mm) to avoid cable vibration. Refer to Figure 20 for air line attachment and Figure 21
for axle attachment.
Fig. 20
4012336a
3"
(76 MM)
3"
(76 MM)
ZIP TIES ON AIR LINES
Fig. 21
4011417a
3"
(76 MM)
SENSOR
CABLE