Appendix II
7.1.4
Sensor Extension Cables at the ECU
On valves that are tank mounted with no trailer structure nearby, or have remote-mounted cables, the
sensor extension cables are attached to the air lines. Cable clips are preferred over zip ties. It is important
to remember that cables should be fastened in a manner where the cable is secured enough where the
cable will not move or chafe against what it is mounted to. A small amount of slack should be present to
ensure that the cables do not become taut after installation or the servicing of components. Figure 18 and
Figure 19 illustrate the correct amount of slack in the sensor extension cables and correct attachment to the
air delivery lines for 2S/1M and 4S/ 2M ABS ECUs.
Fig. 18
4012335a
SENSOR CABLE STRAIN
RELIEF FOR ABS 2S/1M
Fig. 19
4012337a
SENSOR CABLE STRAIN RELIEF FOR
ABS 2S/2M-4S/3M