20
6
Installation of the ultrasonic sensors
Observe the following safety instructions for handling ultrasonic sensors:
The surface to which the ultrasonic sensor is mounted must be even and
must be at least 2 mm larger than the ultrasonic sensor (this is required
to protect the drainage holes in the rear against direct high-pressure
cleaning).
Ultrasonic sensors must not to be mounted in a U-profile because this
could cause reflections. WABCO recommends to mount the ultrasonic
sensors mechanically protected to avoid damage.
The ability to detect objects largely depends on the ultrasonic sensors'
positioning on the vehicle. Make sure that the ultrasonic sensors are
installed at a height of at least 40 cm.
No other vehicle components should be installed within the ultrasonic
sensor's range of vision.
The rate of detection depends on object surfaces:
Ultrasound is best reflected by smooth surfaces that are positioned at a
right angle to the sound's direction.
Small and unfavourable surfaces such as meshed structures, furry
or hairy surfaces at an oblique angle to the sound's direction are not
detected so easily.
Installation of the ultrasonic sensors
Summary of Contents for TAILGUARD
Page 1: ...TAILGUARD FOR REFUSE COLLECTION VEHICLES...
Page 2: ...2...
Page 40: ...40 Notes...
Page 41: ...41 Notes...
Page 42: ...42 Notes...
Page 43: ......