5.3.4 PASSFB (Password for fieldbus)
Command
Parameters
Unit
Group
PASSFB X
x= 0… 10000000
-
EXP
The value inputted here serves as password for the parameterizing via fieldbus. For enabling parametrization
it has to be send via fieldbus to the relating address. For a value of
“0” the password protection is deactivated.
5.3.5 FUNCTION (Choosing operation mode)
Command
Parameters
Unit
Group
FUNCTION X
x= 195|196
-
STD
This parameter allows you to setup the amplifier for up to two valves with one solenoid (e.g. pressure valves,
function 196) or to one valve with two solenoids (directional valve, function 195).
195
-
Controlling a directional valve with two solenoids
196
-
Two independent channels for controlling one solenoid each
5.3.6 CCMODE (Activation of the characteristic linearization)
Command
Parameters
Unit
Group
CCMODE
X
x= ON|OFF
-
EXP
This command will be used for activation or deactivation of the characteristics linearization (CC, CCA and
CCB). Through deactivating this parameter a simple and quick estimation of the linearization is possible.
CAUTION:
If CC command is used, parameters MIN, MAX and TRIGGER have to be considered.
CC and those commands affect each other. Pay attention to that if it is necessary to use both kind
of settings at the same time.