Page 19 of 43
PAM-199-P-PFN
5.2
Parameter list 196
Group
Command
Default
Unit
Description
Basic parameters
LG
EN -
Changing language help texts
MODE
STD -
Parameter view
SENS
AUTO -
Malfunction monitor
PASSFB
0 .
Password for fieldbus parameterization
FUNCTION
196 -
Operation mode
CCMODE
OFF -
Activation and deactivation of the characteristic linearization
Input signal adaptation
AA:UP
AA:DWN
100
100
ms
ms
Command signal ramp times channel A
AB:UP
AB:DOWN
100
100
ms
ms
Command signal ramp times channel B
Output signal adaptation
CCA
CCB
X Y
X Y
-
-
Free definable characteristic linearization
MIN:A
MIN:B
0
0
0.01 %
0.01 %
Deadband compensation
MAX:A
MAX:B
10000
10000
0.01 %
0.01 %
Output scaling
TRIGGER
200 0.01 %
Deadband compensation trigger point
Parameters of the power stage
CURRENT:A
CURRENT:B
1000
1000
mA
mA
Rated solenoid current
500
500
0.01 %
0.01 %
Dither amplitude
DFREQ:A
DFREQ:B
121
121
Hz
Hz
Dither frequency
PWM:A
PWM:B
2352
2352
Hz
Hz
PWM frequency
ACC
ON -
Current loop auto adjustment
PPWM:A
PPWM:B
7
7
-
-
P-Gain of the current loop
IPWM:A
IPWM:B
40
40
-
-
I-Gain of the current loop