WWW.VYNCO.CO.NZ
9
TECHNICAL SPECIFICATIONS - E1V2
Electrical
Ratings
Rated Input Voltage
230V a.c. +- 10% - Single Phase
Frequency
50Hz
Maximum Power
7.4kW
Rated Current
32A maximum
(permanent connection)
Standby Power
<6W
Electrical
Protection
RCCB Protection
None supplied – Type B RCCB
required to be fitted at the
switchboard.
RCCB - minimum 32A – 2 Pole.
Additional Internal Protection
Under/Over Voltage, Short Circuit,
Under/Over Temperature,
Phase Protection
Equipment Protection Class
Class 1
Environmental Ratings
Suitable For Use
Indoors or Outdoors.
Restricted access location
Protection Rating
IP54
Working Temperature Range
-30°C to +55°C
Working Humidity
5% to 95% without condensation
Maximum Elevation
<2000 Metres
Average Mean Time Before Failure
(MTBF)
100,000 operations
Overall Dimensions
211mm x 345mm x 122mm
(L x W x D)
Installation
Surface, wall or post mount
(post not provided)
Weight
< 4.0kgs
Operational Ratings
Activation Method
Plug in and charging starts
automatically after 20 seconds
Emergency Disconnection
Emergency Stop Button
LED Status Indication
Blue – Power Available
Green Flashing – Charging
Red Flashing – Fault
Charging Method
Mode 3
Compliance / Instructions
Electrical Standards Compliance
IEC 61851-1:2017,
IEC 61851-23 (Mode 3)
Supplier Declaration of Conformity
(SDoC) / Instructions
Available from - www.vynco.co.nz
Installation and Operating Instructions available from www.vynco.co.nz