WWW.VYNCO.CO.NZ
6
WIRING INSTRUCTIONS
Caution:
This product must be installed and wired according to the Worksafe Electric Vehicle Charging
Safety Guidelines – available at www.worksafe.govt.nz. All electrical connections are to be
carried out by a New Zealand Registered Electrician.
This EV charger must be permanently connected to a power supply and be supplied from
a dedicated final sub-circuit.
The final sub-circuit and EV charger must be protected by a suitable MCB and RCCB (Type B).
This EV charger requires a Single Phase 32A Supply - (Phase, Neutral and Earth).
Vynco recommends that this EV charger is protected by a Type B RCCB fitted at the switchboard.
Wiring:
• Run the cabling to the EV Charger position:
• On the EV charger remove the 6 screws holding
on the back plate.
Caution – Do not lose the screws as they
are required to maintain the IP rating.
• Incoming supply must enter the charger either:
1. Through the back entry gland
2. Through the surface mount gland
Back Wiring
Run the cabling through the hole in the mounting plate into the wall
cavity.
Surface Wiring
Run the cabling into the bottom of the EV charger. Only use the left
hand gland (viewed from front).