1. Warning

This device is a scientific precision instrument designed to last for many years with a minimum of maintenance. 

It is built to high optical and mechanical standards and to withstand daily use. 

We remind you that this manual contains important information on safety and maintenance, and that it must 

therefore be made accessible to the instrument users. 

We decline any responsibility deriving from incorrect instrument use uses that does not comply with this manual

2.  Safety Information

Avoiding Electrical Shock

 

Before plugging in the power supply, make sure that the supplying voltage of your region matches with the opera-

tion voltage of the equipment and that the lamp switch is in off-position.

Users should observe all safety regulations of the region. The equipment has acquired the CE safety label. How-

ever, users do have full responsibility to use this equipment safely.

Please follow the guidelines below, and read this manual in its entirety to ensure safe operation of the unit.

3.  Package Contents

VisiCamB5

DESCRIPTION

QUANTITY

Camera

1

USB2.0 cable

1

0,5X projection lens

1

Reduction ring 30 mm

1

Reduction ring 30.5 mm

1

Micrometric slide

1

VisiCamP6 / OPTKC-PF

DESCRIPTION

QUANTITY

Camera

1

USB3.0 cable

1

Micrometric slide

1

OPTKC-P20CC

DESCRIPTION

QUANTITY

Camera

1

USB3.0 cable

1

Draining tube

1

Power supply

1

Schuko power cord

1

UK power cord

1

Swiss power cord

1

Micrometric slide

1

Summary of Contents for 630-2957

Page 1: ...INSTRUCTION MANUAL Version 1 0 Issued 07 02 2020 Model European Catalogue Number VisiCamB5 630 2957 VisiCamP6 630 2958 OPTKC P20CC 630 2959 OPTKC PF 630 2960 VWR USB cameras 1 2 ...

Page 2: ...pe 6 8 1 1 Connection to trinocular port using focusable C mount adapter 6 8 1 2 Connection to trinocular port using projection lens 6 8 1 3 Connection to binocular or monocular head 7 8 2 Parfocality adjustment 8 8 2 1 Using a biological microscope 8 8 2 2 Using a stereomicroscope with C mount adapter 8 8 2 3 Using a stereomicroscope with projection lens 9 8 3 Connecting camera to PC 9 8 3 1 Only...

Page 3: ... region matches with the opera tion voltage of the equipment and that the lamp switch is in off position Users should observe all safety regulations of the region The equipment has acquired the CE safety label How ever users do have full responsibility to use this equipment safely Please follow the guidelines below and read this manual in its entirety to ensure safe operation of the unit 3 Package...

Page 4: ...al items fall out and get damaged 5 Intended use For research use only Not intended for any animal or human therapeutic or diagnostic use 6 Symbols and conventions The following chart is an illustrated glossary of the symbols that are used in this manual CAUTION This symbol Indicates a potential risk and alerts you to proceed with caution 7 Overview 7 1 VisiCamB5 USB 2 0 CABLE SOCKET C MOUNT ...

Page 5: ...5 7 2 VisiCamP6 OPTKC PF 7 3 OPTKC P20CC USB 3 0 CABLE SOCKET BACK OF THE CAMERA C MOUNT EXTERNAL POWER SUPPLY SOCKET USB2 0 CABLE SOCKET USB3 0 CABLE SOCKET OPERATION LED ...

Page 6: ...t adapter 2 Screw the C mount adapter to the camera s thread Fig 1 3 Loosen the clamping screw on the trinocular port of the microscope remove the dust cover and install the camera C mount unit previously as sembled Fig 2 4 Tighten the clamping screw firmly Fig 3 8 1 2 Connection to trinocular port using projection lens 1 Remove the dust cover from camera and from projection lens 2 Screw the proje...

Page 7: ...the projection lens into the empty hole of the photo tube Fig 6 F Fig 5 ig 5 F Fig 6 ig 6 8 1 3 Connection to binocular or monocular head Any monocular or binocular microscope ster eomicroscope 1 Remove the dust cover from camera and from projection lens 2 Screw the projection lens to the camera s thread Fig 7 3 Remove one eyepiece from the observation head Fig 8 F Fig 8 ig 8 F Fig 7 ig 7 ...

Page 8: ...able on the microscope 40x or 60x and focus the speci men again 3 Turn on the live view on the camera without changing the focus on the microscope 4 While observing the image on the screen monitor adjust the focus by turning the knurled knob on the C mount adapter Fig 11 F Fig 9 ig 9 F Fig 10 ig 10 8 2 2 Using a stereomicroscope with C mount adapter 1 Use a low power magnification and focus the sp...

Page 9: ...rfocality adjustment is obtained when the same focus is reached while looking into the eye pieces and on the screen monitor 8 3 Connecting camera to PC 1 Connect one terminal of the USB cable to the camera connector and the other terminal to a USB port on the computer Fig 14 NOTE USB3 0 cameras can be connected to a USB2 0 port The camera will operate normally with some limitations due to improper...

Page 10: ...will attract dirt and dust that will settle on the sensor Periodically empty the drainage tube repeating in reverse order the operations described above F Fig 16 ig 16 F Fig 17 ig 17 9 Use of camera The camera is driven by the software PROVIEW You have to run the setup exe file for the software installation At the end of the installation it is possible to start the software NOTE no driver installa...

Page 11: ...Micrometric slide 26x76mm with 2 scales 1mm 100div for biological microscopes 10mm 100div for stereomicroscopes For biological microscopes calibration 1 DIV 0 01mm For stereo microscopes calibration 1 DIV 0 1mm 0 1 2 3 4 5 6 7 8 9 10 ...

Page 12: ...he best results use the VWR cleaning kit If you need to send the microscope to manufacturer for maintenance please use the original packaging 12 Technical service Web Resources Visit the VWR s website at www vwr com for Complete technical service contact information Access to VWR s Online Catalogue and information about accessories and related products Additional product information and special of...

Page 13: ...our responsibility to decontaminate the equipment in case of biological chemical and or radiological contamination so as to protect from health hazards the persons involved in the disposal and recycling of the equipment For more information about where you can drop off your waste equipment please contact your local dealer from whom you originally purchased this equipment By doing so you will help ...

Page 14: ...14 ...

Page 15: ...15 ...

Page 16: ...orthwest Business Park Ballycoolin Dublin 15 Tel 01 88 22 222 Fax 01 88 22 333 E mail sales ie vwr com Italy VWR International PBI S r l Via San Giusto 85 20153 Milano MI Tel 02 3320311 02 487791 Fax 800 152999 02 40090010 E mail info it vwr com The Netherlands VWR International B V Postbus 8198 1005 AD Amsterdam Tel 020 4808 400 Fax 020 4808 480 E mail info nl vwr com New Zealand Global Science A...

Reviews: