LECTRIC2CMDF-INST.doc
01/25/2018
4
ELECTRICAL CONNECTIONS
1.
Be certain the power is
OFF
before making electrical connections. All wiring are required to comply
with National and/or Local electrical codes and regulations.
2.
The standard LECTRIC 2-C MDF screen operates on 120VAC, 60Hz power supply. Control of the
screen is usually by a SPDT toggle switch with center ‘OFF’ position. Optionally, an IR (Infrared) or
RF (Radio Frequency) remote control or 12VDC-trigger relay can also operate the screen. Please
consult the dealers for details.
Note: The switch’s contacts or relay’s contacts must meet the minimum specification below.
Contact Rating: 10A @ 120VAC, 6A @ 250VAC, 1/4 HP.
3.
Refer to the Wiring Diagram at the end of this manual and make connections as required. All wiring
should be made using a minimum 18-gauge wire.
For installations with 220VAC motor, the equivalent wire colors for the motor are as follow:
120VAC motor
220VAC motor
Description
Green Yellow/Green Ground
White
Blue
Neutral
Red
Black
Screen up direction
Black
Brown
Screen down direction
For any 220VAC installation that equipped with a 120VAC motor, a step down transformer is
provided for this application. Simply follow the Wiring Diagram and connect the transformer as