background image

LECTRIC2CMDF-INST.doc 

       01/25/2018 

 

 

4

ELECTRICAL CONNECTIONS 

 

1.

 

Be certain the power is 

OFF

 before making electrical connections. All wiring are required to comply 

with National and/or Local electrical codes and regulations. 

2.

 

The standard LECTRIC 2-C MDF screen operates on 120VAC, 60Hz power supply. Control of the 
screen is usually by a SPDT toggle switch with center ‘OFF’ position. Optionally, an IR (Infrared) or 
RF (Radio Frequency) remote control or 12VDC-trigger relay can also operate the screen. Please 
consult the dealers for details. 

 

Note: The switch’s contacts or relay’s contacts must meet the minimum specification below. 

 

 

Contact Rating: 10A @ 120VAC, 6A @ 250VAC, 1/4 HP. 

3.

 

Refer to the Wiring Diagram at the end of this manual and make connections as required. All wiring 
should be made using a minimum 18-gauge wire. 

For installations with 220VAC motor, the equivalent wire colors for the motor are as follow: 

120VAC motor 

220VAC motor 

Description 

 

Green Yellow/Green  Ground 

 White 

Blue 

Neutral 

 

Red 

Black 

Screen up direction 

 

Black 

Brown 

Screen down direction 

For any 220VAC installation that equipped with a 120VAC motor, a step down transformer is 
provided for this application. Simply follow the Wiring Diagram and connect the transformer as 
shown. Be sure to place the transformer in a safe and well-ventilated location. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 